CRU-XP
Universal controller
Page 4 of 4 Subject to technical modifications CRU-XP_V1.70_PI_2019-04_EN
Place the device with the upper guide edge on
the top-hat rail.
Then press the device gently downward until it
engages with the fastening safety catch on the
top-hat rail.
When wiring the data lines, please refer to the description of the "FRIGOENTRY bus system".
We recommend the use of shielded cables for sensor extension.
Technical data
230V~, +10% / -15%, approx. 5VA
2 x current input, 4…20mA (I1 and І2)
Inputs for voltage-free contacts:
4 x multifunction input
4 x normally open contact, 230V~, 4(2)A, rated voltage 250V~
1 x 0…10V=, non-isolated, max. load 1mA, alternatively for actuating
an electronic relay ATV230
Single-chip microcomputer, data memory
Monitoring of connected sensors, self-monitoring of data memory
and microcomputer
3-wire CAN bus interface with integrated power supply, galvanically
isolated, service socket
(WxHxD) 106 x 90 x 58mm (DIN 43880)
Top-hat rail TH 35-15 or TH 35-7.5 (DIN EN 60715)
Operation: 0...+55°C, storage: -25...+70°C
CE conformity
− 2014/30/EU (EMC Directive)
− 2014/35/EU (Low Voltage Directive)
EAC conformity
− TR CU 004/2011
− TR CU 020/2011
NOTE
You can find more information about the device in the Wurm Infocenter.