GB - 9
Technical specifications
Type HDR 160
Compact
HDR 185
Power
HDR 185
Power
Plus
HDR 215
Premi-
um
Main Supply
Voltage V 230
Current type Hz 1~ 50
Connected load kW 2.3 2.7 3.2
Protection (slow, char. C) A 16
Maximum allowed net impedance -- 0.364
+j0.216
0.2679 0.302
+j0.189
Type of protection -- IPX5
Extension cord 30 m mm
2
2.5
Water connection
Max. feed temperature °C 60
Min. feed volume l/h (l/min) 600 (10) 700 (11.7) 720 (12)
Suck height from open container (20 °C) m 0.5
Max. feed pressure MPa (bar) 1 (10)
Performance data
Operating pressure of water (using standard
nozzle)
MPa (bar) 13 (130) 15 (150) 15 (150) 17 (170)
Size of standard nozzle -- 031 032 028
Max. operating over-pressure MPa (bar) 16 (160) 18.5
(185)
18.5
(185)
21.5
(215)
Flow rate l/h (l/min) 480 (8.0) 500 (8.3) 500 (8.3) 500 (8.3)
Detergent suck in l/h (l/min) 0...35 (0...0.6)
Max. recoil force of trigger gun N 21 25 25 21
Fuel
Amount of oil l 0.38 0.35
Oil grade -- SAE 15W40
Dimensions and weights
Length mm 360
Width mm 375 400 375
Height mm 925
Typical operating weight kg 26.1 28.9 30.8 29.6
Values determined as per EN 60335-2-79
Hand-arm vibration value
Hand spray gun m/s
2
<2.5 2.7 2.7 <2.5
Spray lance m/s
2
<2.5 <2.5 <2.5 <2.5
Uncertainty K m/s
2
1111
Sound pressure level L
pA
dB(A) 74757572
Uncertainty K
pA
dB(A) 2221
Sound power level L
WA
+ Uncertainty K
WA
dB(A) 89919186
22