20
If the vehicle battery is properly connected to the
device, the Ready LED lights up green.
Start the vehicle engine.
Note
If the engine does not start within 5 seconds, stop the start-
up process. Wait another 30 seconds and try again.
Attention!
Do not attempt more than ve starts in succession within a
period of 15 minutes. After the fth attempt, allow the device
to cool down for 15 min. before trying again.
Switch o the device at the On/O switch
First, remove the black clamp then the red clamp.
Recharge the device as described.
Manual override mode
Danger posed by spark build-up
and severe heat.
Spark and reverse battery protection are deactivated in this
function.
Use this function with extreme caution and only in
exceptional circumstances.
Check the exact polarity of the vehicle battery before-
hand
Pay particular attention that the red positive terminal
clamp is connected to the positive terminal and the
black negative terminal clamp is connected to the nega-
tive pole of the vehicle battery of the vehicle.
Never touch the red positive terminal clamp with the
black negative terminal clamp / ground point on the
vehicle.
Do not use this function in the case of any uncertainty.
Connect the negative (black) battery clamp to the nega-
tive (NEG, N, -) battery terminal or the vehicle body.
Press twice and hold down the On-o switch button
button for approx. 5 seconds to trigger this function. The
green ready LED will ash.
Connect the positive (red) battery clamp to the positive
(POS, P, +) battery terminal.
Override mode starts and the override mode ashes
white.
ashlight function
Light button: Press and hold > 1sec:
1xFull brightness
2x Flashing light (3x — — —, 3x - - - ,... SOS)
3x Flashing light strobe mode ( - - - .....)
3x O (> 1 sec)
Maintenance and care
Charge the battery immediately after purchase,
after each use and also every 30 days for at
least 24 hours.
The appliance must not be allowed to become wet. Protect
the appliance against humidity and moisture! Clean with
a dry cloth only. Some cleaning agents damage plastic or
other insulated parts. Keep the device clean and dry, free
from oil and grease. Store the device in a covered, cool and
dry place.
Check the unit before each use for damage. If damaged,
have the device repaired before use.
Troubleshooting
Fault Cause
Remedy
The vehicle engine will not start. Clamps are not making
a good connection to the
battery.
Check for poor connection to battery and frame.
Make sure connection points are clean.
The jump starter is not
turned on.
Press the On/o switch to turn on the jump starter.
Check the polarity and
change the clamps if
necessary.
Disconnect the jump starter and reverse the clamps.
The internal battery is too
low.
Charge the internal battery if the Battery status indica
-
tor shows less than 75%.
The vehicle’s battery is
defective.
Have the battery checked.
The internal fuse is blow. have the fuse replaced. Contact MASTERSERVICE.