CHARGING MODES
# VOLTAGE MODE DESCRIPTION OUTPUT
BATTERY
SIZE
5 6V Normal
For charging 6-volt Flooded, Gel, Maintenance-Free
batteries. When selected, the LED will illuminate.
7.3V /
3.8A
12Ah-120Ah
6 6V
Cold/
AGM
For charging 6-volt batteries in cold temperatures
below 50°F (10°C) or AGM batteries.
7.4V /
3.8A
12Ah-120Ah
7 12.8V Lithium
Press & Hold Mode
For charging 12.8-volt lithium iron phosphate
batteries. Lithium mode will only function if the
battery voltage is 11.6V or greater. When
selected, the LED will illuminate.
14.5V /
3A
8Ah-50Ah
8 12V Recover
Press & Hold Mode
For recovering and repairing and storing, old,
idle, damaged stratied or sulfated Flooded,
Maintenance-Free Lead Acid batteries. When
selected, the LED will illuminate. NEVER USE
RECOVER MODE ON LITHIUM BATTERIES.
14.8V /
2Ah
1.2Ah-120Ah