Why state-of-charge and time-to-go readout are not accurate on Xantrex Monitor?
- JJennifer HarrisAug 13, 2025
If the state-of-charge and/or time-to-go readout on your Xantrex Monitor are inaccurate, ensure that all current flows through the shunt, verifying the negative terminal of the battery only contains the wire going to the battery side of the shunt. Also, check the battery capacity in Function F01, CEF in Function F09, Peukert Exponent in Function F10, Battery temperature in Function F11, and Temperature coefficient in Function F12.