EasyManua.ls Logo

Xcortech X3300W - X3300 CC Setup Operation; Flash Control (FLM); Boss Role (boSS); Count Down Setting (cnt)

Xcortech X3300W
2 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mode Selector select to ST (Setup Mode)
That can be setup below function (reference above flowchart for setup)
FLM (flash control) : on/oFF, Setup Tracer BB on/oFF
Boss : Team Battle Mode to limit team for BB counts
Link: http://youtu.be/leCexUHqET0
cnt (count): 5-9999, Preset initial count down value
WArn (warn): 1-100 & oFF, low ammo warning
(When low ammo warning, display will flash in count down mode)
AEG.b (AEG battery): Display AEG’s battery voltage
(need to link with X3300SCU)
Unit: M/F, Set unit for speed (meter/sec , feet/sec)
APo (auto power off): 1-80 mins, Set auto power off
Eco (save display power): on/oFF, auto adjust the screen brightness to
maximize battery life
ttS (total shot count): 0-65000, Display total count, push and hold the “Data
Wheel” 3 sec to reset count.
ScU (Shot Control Unit): Set burst round shot
(see Ch5 )
rSt (reset): Reset to factory setting
CH-4. X3300CC Setup operation
Need to connect X3300SCU (optional)
b.rnd : oFF & 2-10 : Burst fire setting 2-10.
b.tyP : 5.0-9.0 Voltage & oFF : Set low power level. The AEG will vibrate and
shutdown when lower battery level is detected.
Select oFF to disable this function.
MEM : 1-8 : Set burst control channel, each channel includes the following factors:
cnt value
Warn value
b.rnd number
b.tyP select
bind information
bind : Binding/paring with X3300SCU
Exit : Exit
SCU setting Video: http://youtu.be/BJZ32J4UbQA
The Xcortech product information : http://goo.gl/W11LOK
CH-5. X3300W ScU (shot control unit) setup
ScU
Burst Round
b.rnd
Adjust from
oFF, 2 ~ 10
Select battery type to active
low battery protect
b.tyP
Bind a EGATE
bind
Exit to upper layer
EXit
Select memory slot
MEM
Select slot from
1 ~ 8
Bind a ScU to
selected memory slot
5.0-9.0V Adjustable
oFF (Stop portect)
Low power
Warning and
shutdown level
Binding X3300W and X3300SCU
V1.17
Flash control
FLM
Speed Unit
Unit
M: Meter
F : Feet
Auto Power Off
APo
Adjust from 1 to 80
minute
Down count initial value
cnt
Low ammo warning level
WArn
Adjust from 5 to 9999
Adjust from 1 to 100
0 means warning oFF
Save Display Power
Eco
on
oFF
Shot control unit
ScU
Burst Round
b.rnd
Adjust from
oFF, 2 ~ 10
Set stop voltage to
protect AEG battery
b.tyP
Adjust from
oFF, 5.0 ~ 9.0V
oFF is stop protect.
Bind a EGATE
bind
Exit to upper layer
EXit
Select memory slot
MEM
Select slot from
1 ~ 8
Bind a ScU to
selected memory slot
Reset CC
rSt
no
yES
Total shot
ttS
Show total shot number.
Valid from 0 to 9999
Show AEG battery
AEG.b
Show AEG battery volt
continuously.
(Need ScU)
Enter the boss role
boSS
Generate boss ID
?.?.?.?.
Stop fire
StoP
no
yES
on
oFF