深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
2 / 15
1st. Overview
XKC-C352 Intelligent non-contact liquid level controller and XKC-Y25-V liquid level sensor realize the function of
liquid level high and low control: when the container liquid level is too low, the low liquid level alarm signal sent by the
low liquid level sensor is triggered to trigger the C352 controller to close the relay to start the water pump Add the liquid
level, when the liquid level reaches a certain height, the high liquid level sensor sends out a signal to trigger the C352
controller to disconnect the relay and automatically stop the water pump to work in a cycle. Thereby, the function of
automatic control of the container liquid level is realized, and the container liquid level is kept stable.
2nd.Product Features
1.AC180V~250V power supply
2. Relay dry node output, suitable for various load control
3. The control is diversified, and the pump can be controlled in manual or automatic mode
4. The installation is simple and convenient, it can be installed with screws or electric box tracks
3rd.Technical Parameters
C352 Intelligent non-contact liquid level controller
Working current ≤110 mA, static current consumption ≤20mA
Resistive load below 1.6KW (overload or three-phase load needs to be installed
with AC contactor)
Inductive load below 1KW (overload or three-phase load needs to be installed
with AC contactor)
Inductive loads refer to loads with inductive coils, such as motors,
electromagnets, solenoid valves and so on.
800W (resistive load) normally open / normally closed output
Normally open/normally closed output
Low sensor signal input;
High-position sensing signal input;