SFD2081
High 16 bits of Electrical origin
position
SFD2082
Mechanical back to origin
parameter setting
Bit0Switch state setting of near
point, 0 Normally ON
1Normally OFF
SFD2083
Terminal setting of near point
signal
Bit0~bit7Assign the number of
terminal X, 0Xff for not terminal
SFD2084
Z phase terminal setting
Bit0~bit7Assign the number of
terminal X, 0Xff for not terminal
SFD2085
Limit terminal setting
Bit7~bit0Assign limit 1 number
of terminal X, 0Xff for not
terminal
Bit15~bit8 Assign limit 2
number of terminal X, 0Xff for
not terminal
SFD2086
Terminal setting of origin
auxiliary signal
Bit0~bit7Assign the number of
terminal X, 0Xff for not terminal
SFD2087
Terminal setting of zero clear
CLR signal output terminal
Bit0~bit7Assign the number of
terminal Y, 0Xff for not terminal
SFD2088
Low 16 bits of return speed VH
SFD2089
High 16 bits of return speed VH
SFD2090
Low 16 bits of return speed VL
SFD2091
High 16 bits of return speed VL
SFD2092
Low 16 bits of crawling speed
SFD2093
High 16 bits of crawling speed
SFD2094
Low 16 bits of mechanical origin
SFD2095
High 16 bits of mechanical
origin
SFD2096
Z phase number
SFD2097
CLR signal delay time
Default 20, unit: ms
SFD936
G instruction parameter group
using choice
Choose the G instruction
parameter group
SFD2120
Low 16 bits of pulse default
speed
Only when speed is 0, default
speed is used to transmit pulse.
First set of
parameters
SFD2121
High 16 bits of pulse default
speed
SFD2122
Accelerating time of pulse
default speed
SFD2123
Decelerating time of pulse
default speed
SFD2124
Acc and Dec time of tween
SFD2125
Reserved