EasyManua.ls Logo

XOCECO LET3250 - Page 10

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
AV AV selection 3 AV input select(3=AV1/AV2/S/DVD)
MTS MTS IC selection 1/0 0=nothing,1=72700 2=AN5832
V.OFF.MOTE Turn off model 1 0=discharge,1=close
PWR.MEM Turn on model 0/2 0=standby,1=auto turn on,2=memory
1115 select LV1115 0 fixed,0=nothing;1=have
BLCK GROND
No signal background
selection
1 0=nothing 1/3=blue background;2=black background
N/PN
South America and North
America selection
1/0 0=south america;1=north america
1115(the unit no use)
VOL.OFFSET 0
GAIN 3
PWM LOGIC 0
AVL MODE 2
AVL DET LEVEL 0
AVL SLOPE 0
PWM SET
PWM.VOL Volume control of PWM set 1 fixed
1-CHIP.VOL Volume control of mono 0 fixed
VOL 1 1% volume control speciality 20 fixed
VOL 25 25%volume control speciality 60 fixed
VOL 50 50%volume control speciality 90 fixed
VOL 75 75%volume control speciality 100 fixed
72700
ALC ALC 1 fixed ,1=ALC ON
VOL
Baseband model ,input level
adjustment
0 The unit no use
SAP LEVEL SAP level 1 fixed
SIF.M/BB.M SIF and baseband model 0 fixed,0=SIF MODE 1=BB MODE
5832
AGC 1 fixed
Note:above “/” are the adjustment data for north america, below it are for south america.