Series EJ, ET, EY, FJ & FR
102002-177 Rev M2
4
\1020\02177M2.doc 17 Jun 2019
FR Model
Designator: F1 & F2
Located: On rear panel.
XP Glassman P/N: F005-08
Description: Fuse, cartridge, 8A, 250V, Type T, ¼” x 1 ¼”.
FR Model (F22 Option)
Designator: F1 & F2
Located: On rear panel.
XP Glassman P/N: F005-03
Description: Fuse, cartridge, 3A, 250V, Type T, ¼” x 1 ¼”.
WARNING! BEFORE REPLACING ANY FUSES THE POWER SUPPLY MUST BE
DISCONNECTED FROM THE MAINS.
TO DISCONNECT THE POWER SUPPLY FROM THE MAINS, THE POWER SUPPLY
CORD MUST BE UNPLUGGED.
There are no other user-serviceable components. Return supply to factory for
replacement of other components by qualified technicians.
(For instructions on changing the polarity in reverse polarity models see Polarity Reversal
Sections elsewhere in this manual).