781N Electric Latch Pullback Controller
Installation Instructions
INSTALLATION
For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the
Canadian Electrical Code. Transformer model BE31763001 by Basler Electric and transformer
model 2010028 by Galaxy Transformer and Magnetics have been certified for UL and C-UL
applications. Transformer model A41-130-28A34 by EWC has been certified for UL applications
only.
The 781N enclosure should be securely fastened to the wall using the four 1/4 inch diameter
mounting holes located in the back of the box. Position the enclosure so that the transformer is
located on the left-hand side. The 781N must not be installed outdoors.
For the 120VAC power input, terminal block TB1 will accommodate up to 12 AWG wire (solid).
Conduit must be used to provide an adequate earth ground to the enclosure.
NOTE: The maximum input current is 750mA.
The 781N is designed to be used with electric latch pullback exit devices. Use the chart below to
determine the correct wire gauge per given length of two-conductor cable that will be run from
the 781N to each exit device. Do not exceed the maximum length listed with each wire gauge.
WIRE GAUGE MAXIMUM LENGTH OF TWO-CONDUCTOR CABLE
16 AWG 40 FEET
14 AWG 60 FEET
12 AWG 100 FEET
Up to two devices can be used with the 781N. If only one device is to be used, wire to the
"DEVICE ONE" location at TB3, terminals 5 and 6.
NOTE: Be sure to observe polarity when connecting devices 1 and 2 to TB3.
(Refer to the wiring diagram located on the lid of the controller.)
An ASSA ABLOY Group brand
80-9477-0781-010 (01-13)
Question and Answer IconNeed help?

Do you have a question about the Yale 781N and is the answer not in the manual?

Yale 781N Specifications

General IconGeneral
BrandYale
Model781N
CategoryController
LanguageEnglish

Summary

INSTALLATION

C-UL Listed Applications & Transformer Models

Installation compliance for C-UL Listed applications and certified transformer models.

Enclosure Mounting & Positioning

Securely fastening the 781N enclosure and positioning it correctly.

120VAC Power Input & Grounding

Connecting 120VAC power input, wire gauge, and grounding requirements.

Wiring for Exit Devices

Chart for wire gauge, max cable length, and connection for exit devices.

STANDARD OPERATION

Single vs. Dual System Latch Pullback

Two methods: single system (sequential) or dual system (independent control).

Delay Time Adjustment

Adjusting latch pullback delay using pots R2/R4 for different switch types.

Exit Device Operation Mechanism

Explanation of the pulse module, coils, and sensor in exit devices.

OPERATION WITH AUTOMATIC DOOR OPERATOR

Automatic Door Operator Control

Using the 781N outputs to control automatic door operators.

OPERATION WITH FIRE ALARM

Fire Alarm Interface Setup

Wiring to fire alarm contacts and enabling interface via jumper PJ2.

AUXILIARY POWER SOURCE OUTPUTS

Auxiliary Output Specifications & Caution

Two power-limited outputs, voltage ranges, isolation, and voltage compatibility caution.

TROUBLESHOOTING

Pre-Troubleshooting & Output Behavior

Check for binding latches and understand output behavior during faults.

Symptom: No Pullback Causes

Common causes for devices failing to pull back, including wiring and component issues.

Symptom: Immediate Pullback Causes

Causes for devices pulling back immediately upon power application, like wiring shorts.

Symptom: Buzzing Sound Causes

Reasons for a buzzing sound from the exit device, such as binding latches or module issues.

TROUBLESHOOTING & NOTES

Troubleshooting Specific Issues

Further troubleshooting for no pulse, immediate pullback, and buzzing sounds.

UL Listing & Fail Secure Design

Unit's UL294 listing and the fail-secure design of the power output.