EasyManua.ls Logo

Yale ESC030AC - Page 40

Yale ESC030AC
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STATUS
CODE
DISPLAY MESSAGE RECOVERY METHOD CIRCUIT
12544 12544 Re-key RH Traction
Node 5
DESCRIPTION BEHAVIOR
Wrong Battery voltage connected to truck, or out
of range - (RH Node 5)
Truck disabled.
Probable Causes and Test Procedures
1. Verify a proper battery (36V Nominal) is connected to the truck.
a. Does the battery label indicate 36 volts DC nominal, and the proper A/hr rating?
b. Has the battery charger been disconnected from the truck?
YES- Proceed to Step 2
NO- Disconnect charger or replace with correct battery.
2. Measure Actual Battery Voltage:
a. Is the actual battery voltage between 28V and 38V DC?
YES- Proceed to step 3.
NO- Disconnect and charge the battery if (< 28V) or allow battery to settle charging if
(>38V).
3. Check High Current power cables:
a. Check for B+ Voltage at input POS on the line contactor, with a ground reference to the B− Stud
Terminal.
YES- Proceed to step 5.
NO- Proceed to step 3b.
b. Check continuity from B− battery connector to B− stud.
c. Check continuity from B+ battery connector to POS Line contactor lead.
YES- Tighten loose bolts / connections, repeat step 3a.
NO- Repair wiring / crimp terminal / stud as necessary to regain continuity.
Troubleshooting 2200 YRM 1415
36