EasyManua.ls Logo

Yale ZAPI MPW045-E - Page 29

Yale ZAPI MPW045-E
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2200 YRM 1067 Troubleshooting
Dash Display
Controller LED Handset or PC
AL6 6Flashes STBY I HIGH
CONDITION
Controller detects motor current during standby mode.
TRUCK RESPONSE
Traction and hydraulic functions disabled.
POSSIBLE CAUSES AND TEST PROCEDURES
Damaged controller.
Replace controller.
LOGIC
Occurs if controller
detects motor currents during standby mode.
Dash Display
Controller LED Handset or PC
AL7 7Flashes THERMAL PROTECTION
CONDITION
Controlle
r temperature is out of operating range.
TRUCK RESPONSE
Traction functions reduced below 10 C(14F)
and above 75
C (167 F). Traction and hydraulic
functions disabled above 90
C (194 F).
POSSIBLE CAUSES AND TEST PROCEDURES
Controller temperature is too hot/cold.
If too hot, allow the unit to cool off.
LOGIC
This alarm is generated
when the controller temperature outside
is
10 to 75 C (14 to 167 F).
25

Related product manuals