8
In weighing mode, keep pressing [ Func ] for 5 seconds more, it will enter operator setting
mode (mode P), there are 12 modes from P1 to P12 for option, press [ * ] to choose the
mode and press [Tare] to change the parameter. The description of parameter as follows:
1、P1 x kg Lb change
x=1: kg display
x=2: Lb display
2、P2 x automatically power off
x=1: No this function
x=2: Power off 10 minutes later
x=3: 20 minutes
x=4: 30 minutes
3、P3 x Baud rate setting
x=1: 9600
x=2: 4800
x=3: 2400
x=4: 1200
4、P4 x RS232 Net/Gross weight output option
x=1: Net weight output
x=2: Gross weight output
x=3 Tare weight output
5、P5 x RS232 output mode option
x=1: No transmission (RS232 stop)
x=2: Continuous transmission
x=3: Continuous transmission when stable
x=4: Command mode
(Z:zero,T:tare,R:transmit weight data once time)
x=5: scoreboard display (Current loop output)
x=6: scoreboard and RS232 simultaneously perform
6、P6 x Power saving function setting
x=1: No power saving function
x=2: With power saving function
x=3: Invalid
7、P7 x Zero-tracking scope
x=1: 0.5e
x=2: 1.0e
x=3: 1.5e
x=4: 2.0e
x=5: 2.5e