EasyManuals Logo

Yaohua Weighing System YH-T6 User Manual

Yaohua Weighing System YH-T6
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
2
4
T
he indicator returns to
zero
[ 0.00]
Make the indicator return to zero
(Note: the data with 2-bit decimal points is an
example
5
Press
(Note:
accumulative-displ
ay function)
[******] Display accumulative wei
g
ht for around 2
seconds, ”accu” light is on
[t **] Display accumulative times for around 2 seconds
[******] Return to weighing mode, “accu” light is off
6
Press
[C-Add] Clear all accumulative wei
hts and all wei
hin
times
6. Kg/lb switch: Under weighing mode, press to switch between kg & lb.
(NOTE: Once it switched, all the accumulative weight or times will return to zero.)
7. Power-saving mode:
When weighing data is stable, 3 minutes later it will enter power-saving mode, the indicator shows [ - ] and it
flashes from left to right.
8. Built-in rechargeable battery
Connect to AC power, whether the power is on or off, the weighing indicator begins to charge the battery. (When
power is off, the charging speed will be faster)
The charging time is around 24~28 hours. It can be used for 36 hours after fully charged (typically data).
9. Low-voltage alarm and cut off:
When the battery’s voltage is lower than around 3.3V, the indicator will show [bAttLo] every 30 seconds to mean
the voltage is low and there’s sound of moo for reminding.Customers shoud charge the battery immediately. If
continue to use,three miniutes later, the indiator will switch off automatically to protect the rechargeable battery.
10. Information introduction:
Information
displayed
Meanin
g
Solution
[Err 03] Overload
1. If the indicator has not been calibrated, you should do it;
2. Decrease the weight that loaded to normal range;
3. Re-set full span for the indicator
[Err 05] or
the exit of
self-inspection
when power is on
Indicator doesn
t connect
with load cell, or indicator
A/D part is damaged, or
load cell doesn’t work
Please check the connection between indicator and load
cell, or let the manufactory repair
[Err 11]
Calibration load error
1. Please confirm the correctness of actual load weight and
input
2.Recalibate after adjust the division
[ ---- ]
Indicator internal running
Please kindly wait, don’t do any operation
[------]
Display the minus overflow
of weight
1 If it’s under the mode of 1b,please chan
g
e it back to be
kg display mode
2 Add more goods on the platform
11. Maintenance:
1).To guarantee the indicator’s cleaning and lifetime, the indicator shouldn’t be placed directly under sunshine and
should be set in the plain space.
2).The indicator can’t be placed into the place where dust pollution and vibration are serious.
3).Load cell should connect with the indicator reliably, and the system should be well connected into ground. The

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yaohua Weighing System YH-T6 and is the answer not in the manual?

Yaohua Weighing System YH-T6 Specifications

General IconGeneral
BrandYaohua Weighing System
ModelYH-T6
CategoryAccessories
LanguageEnglish

Related product manuals