EasyManua.ls Logo

YIERYI MH1210A - User Manual

YIERYI MH1210A
3 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Intelligent temperature controller, Energy-saving and practicality
Microcomputer Temperature Controller
«User manual of MH1210A»
It suits most users in different environments for automatic intelligent control system of many kinds of
refrigeration, heating equipment. Refrigeration and heating mode could be set through the menu, the procedure
has been set the power outage permanent memory function.
Specifications:
1. working voltage: 12V DC or 220V AC
2. measurement range: -40 C~120 C; measurement error: ±0.5°C
3. control range: -40°C~120 C; temperature control precision: separation rate: 0.1°C; slewing range of
temperature: it could be adjusted in the range of 1 ~30°C
4. temperature sensor: NTC 25 C=10K B3435 ±1 % (1 miter length, no positive or negative)
5. output load: normally open 10A/AC220V
6. working environment: temperature: -20°C~70 C; humidity : 90%RH none moisture condensation ;
7. dimension of whole unite : 75(W)x34.5(H)x85(W) mm
8. trepanning dimension : 71(W) x 29(H) mm;
Operation instruction:
Press "set" button for 3s get into the procedure menu code mode, display the code "HC". Press "A" or "V" for
cyclical selection of parameter code of "HC-CP-LA-HA-PU-CA".
To enter a code, press the "Set" button, press the "A" button or the "V" button to change to the desired data and
press "Set" to save and exit;
Control the temperature set: press "Set" button, display blink and it is the default setting. Press "A " or "V " to
change the data and save automatically. (press on "A" or "V" for 2s or more to increase the adjusting speed )
heating control: when the temperature control mode ( code is HC) was H, e.g. the setting control temperature is
28 C , slewing range of temperature is 2 C , when the environment temperature >= setting temperature (28'C),
the relay will switch off and stop the output load; when the environment temperature <=setting temperature (28
C ) - slewing range of temperature (2 C ) and set "delayed start” before, the reply will switch on and output load
again, (if the delayed start function doesn't need, set the delayed start (code PU) to 0)
refrigeration control: when the temperature control mode (code is HC) was C, e.g. the setting control
temperature is 28’C, slewing range of temperature is 2 C, when the environment temperature <=after setting
"delayed start" time, the relay will switch on and sart output load.(suggest "delayed start" time to the default
setting time to protecting the compressor, please set the (code PU) to) if it doesn't need):
Question and Answer IconNeed help?

Do you have a question about the YIERYI MH1210A and is the answer not in the manual?

Summary

Microcomputer Temperature Controller Specifications

Microcomputer Temperature Controller Operation

Control Temperature Set

Press 'Set' for 3s to enter menu mode. Press 'A' or 'V' to change data and save.

Heating Control

When temp >= set temp, output stops. When temp <= set temp minus slewing range, output starts.

Refrigeration Control

When temp <= set temp after delay, output starts. Protects compressor with delay.

Microcomputer Temperature Controller Programming Mode

HC: Heating;Refrigeration Mode

Selects between heating (H) or refrigeration (C) mode.

CP: Slewing Range of Temperature

Sets the temperature difference for relay switching, 1°C to 30°C.

LA: Bottom Limit

Sets the lower bound for temperature control, adjustable from -50°C.

HA: Top Limit

Sets the upper bound for temperature control, adjustable up to 110°C.

PU: Delayed Start

Configures a delay before the output turns on, useful for compressor protection.

CA: Temperature Correction

Allows fine-tuning of the displayed temperature relative to actual.

Microcomputer Temperature Controller Fault Tips

Microcomputer Temperature Controller Installation Wiring

YIERYI MH1210A Specifications

General IconGeneral
Output TypeRelay
Resolution0.1°C
Temperature Range-50°C to 110°C
Control Temperature Range-50°C to 110°C
SensorNTC sensor
Power Supply110~220V
Output10A relay output
Input TypeNTC sensor input
Control ModePID
DisplayLED