3. Iron sleep time setting
For example, Iron sleep time is set to
10 minutes:
Air gun temperature the set immedi-
ately by the third function button, "
SLEEP" flashing, and counterclock-
wise rotation the knob to make the
iron sleep time from 20 to 10, stop
operating four seconds, "SLEEP"
display stops flashing, the program
automatically memory and exit the
function setting, set to complete. If
you want to set the air gun auto/
manual, "SLEEP" display stops
flashing, click the function button,
the specific methods, see the air gun
auto / manual settings.
4. Air gun AUTO/ MANUAL settings
For example, Air gun automatic state
convert the Manual states:
Iron Sleep time is set, immediately, press
the fourth function button, "AUTO" flashing
button, Clockwise rotation the knob to
MANUAL" display flashing, "AUTO" display
crush out, stop the operation for four
seconds, "MANUAL" display stops
flashing, the program automatically
memory and exit the setup is complete.
If you want to set the Fahrenheit /Celsius
display, click the function button in the
MANUAL" display to stop flashing before
specific methods, see Fahrenheit /Celsius
conversion settings.
HOT AIR
Gun temperature
AIR
SOLDERING
HOT AIR
automatically memory and exit the
function setting, set to complete. If
you want to correct iron temperature,
F display stops flashing, click the
function button, and set of specific
methods, see the soldering iron
temperature correction.
6. Soldering iron temperature
correction settings
For example, soldering iron temper-
ature should be reduced by IOOC:
Fahrenheit /Celsius conversion
settings, immediately press the sixth
function button, "SOLDERING"
display flashing, meanwhile soldering
iron temperature display window
shows "00", Clockwise rotation the
knob to make the soldering iron
temperature reduction"-10'
stop
operating 4 seconds, "SOLDERING"
display stops flashing, the program
automatically memory and exit the
feature set, set up is complete. If you
want to correct the temperature of the
air gun, "SOLDERING" display stops
flashing, click the function button, and
specific methods, see the air gun
temperature calibration settings.
SOLDERING
HOT AIRAIR
Counterclockwise
Operation shown in Figure 3-1
Counterclockwise
Clockwise Addend
Rotation meiosis
Function button
Operation shown in Figure 3-2
Clockwise oc
rotation OF
Function button
Note: "OF / 0C" will only show one States,
picture shows the convenient introduction and
Show All.
Operation shown in Figure 5
SOLDERING
HOT AIRAIR
Counterclockwise
rotation AUTO
AUTO
MANUAL
Clockwise MANUAL
SOLDERING
AIR
Counterclockwise
Rotation meiosis
Iron calibration temperature
SOLDERING
HOT AIR
Clockwise Addend
Function button
Note: "AUTO / MANUAL" will only show one
States, picture shows the convenient
introduction and Show All.
Operation shown in Figure 4
Function button
Operation shown in Figure 6
5. Fahrenheit/ Celsius conversion settings
For example, oc state conversion the OF state:
Air gun auto/manual settings, imme-diately press the fifth function button, C
display flashing, clockwise rotation the knob to," OF"flashing, "OC"dispIays off,
stop the operation 4 seconds," OF" display stops flashing, the program
9 10