EasyManuals Logo

YOKOGAWA 734 01 User Manual

YOKOGAWA 734 01
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
11
Resistance Measurement
Range
500
5k
50k
500k
5M
50M
0.1+2 0.05+2
0.5+2
1+2
<1mA
<0.25mA
<25µA
<2.5µA
<1.5µA
<0.13µA
<2.5V 600V rms
0.01
0.0001k
0.001k
0.01k
0.0001M
0.001M
Resolution
Accuracy
73401 73402
Measuring
Current
Open-loop
Vo ltage
Input
Protective
Vo ltage
Accuracy is specified after zero adjustment
(resistance).
Response time: 3 sec max. at 500 to 500k
10 sec max. at 5M to 50M
Continuity Check
Range
Resolution
Measuring
Current
Open-loop
Vo l t age
Input
Protective
Vo l t age
Range of Operation
500 0.1
Approx.
0.5mA
<5V
600V rms
The buzzer turns on for
resistances lower than
100±50.
Maximum Reading 5000
Diode Test
Range Resolution
Open-loop
Voltage
Input
Protective
Voltage
Measuring
Current
(Vf=0.6V)
Accuracy
2.4V 0.0001V
Approx.
0.5mA
<5V 600V rms
1+2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA 734 01 and is the answer not in the manual?

YOKOGAWA 734 01 Specifications

General IconGeneral
BrandYOKOGAWA
Model734 01
CategoryMultimeter
LanguageEnglish