51IM 04P02B01-02E
Recording/Displaying Data
Starting/Stopping the Setup Printout
Setup printout can be started/stopped in a similar fashion to List printout. For Setup
printout, select Setup Start and Setup Stop.
Clearing the Alarm Printout Buffer
Alarm information waiting to be printed is temporarily stored in the buffer memory. This
operation clears all of the alarm information in the buffer. This function can be used to
prevent unneeded alarm printouts from being executed.
1.
Press the 
FUNC
 key.
2.
Press the   key to select Buffer clear and then press the   key.
Func=Buffer clear
3.
Press the   key with Alarm shown on the screen.
The data in the alarm printout buffer is cleared. The screen returns to the data
display screen.
Buffer clear=Alarm
Printing a Message
This section explains the procedure for printing the preset character strings. For details
on setting the character strings, see section 6.8, “Setting the Message String” in the
µ
R20000 Recorder User’s Manual 
(IM 04P02B01-01E) on the CD-ROM.
Note
• Messages can be printed only during trend recording. However, regardless of whether
trend recording is in progress or not, messages waiting to be printed are temporarily
stored in the buffer memory.
• Message printouts are not performed when the chart speed is greater than or equal to
1600 mm/h and 101 mm/h on the pen model and dot model, respectively.
Printing a Message
1.
Press the 
FUNC
 key.
2.
Press the   key to select Message and then press the   key.
Func=Message
3.
Press the   key to select the message number and then press the   key.
The message printout starts. The screen returns to the data display screen.
Displays the preset message.
Message=Message1
Clearing the Message Printout Buffer
Messages waiting to be printed are temporarily stored in the buffer memory. This
operation clears the messages in the buffer.
1.
Press the 
FUNC
 key.
2.
Press the   key to select Buffer clear and then press the   key.
3.
Press the   key to select Message and then press the   key.
The data in the message printout buffer is cleared. The screen returns to the
data display screen.
Buffer clear=Message
*  When the          key or         key is pressed while holding down the SHIFT key, the operation is 