EasyManua.ls Logo

York International P2HMX12F08001 User Manual

York International P2HMX12F08001
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
OIL-FIRED WARM AIR
FURNACE
P2HMX12F08001 P3HMX14F10001
P3HMX20F12001
(Upflow or Horizontal Models)
P3LBX12F08001 P3LBX14F12001
(Lowboy Models)
INTRODUCTION...............................................................2
HEAT LOSS......................................................................2
LOCATION OF UNIT ........................................................2
AIR CONDITIONING.........................................................4
COMBUSTION AIR...........................................................4
CHIMNEY VENTING.........................................................4
OIL TANK..........................................................................6
PIPING INSTALLATION ...................................................6
ELECTRICAL CONNECTIONS ........................................6
CIRCULATING AIR BLOWER..........................................7
OIL BURNER ....................................................................8
FURNACE INSTALLATION SET-UP................................9
MAINTENANCE AND SERVICE.....................................10
OPERATING INSTRUCTIONS .......................................10
TABLE A-1: BECKETT OIL BURNER SET-UP .............11
TABLE A-2: DIRECT DRIVE BLOWER SET-UP ...........11
TABLE A-3: DIRECT DRIVE BLOWER
CHARACTERISTICS ......................................................12
GENERAL DIMENSIONS – P*HMX MODELS ...............14
GENERAL DIMENSIONS – P3LBX MODELS................15
APPENDIX B: WIRING DIAGRAM.................................16
WIRING NOTES..............................................................17
R7184 DETAILED SEQUENCE OF OPERATION..........18
TABLE C-1: ST9103 DETAILED SEQUENCE OF
OPERATION...................................................................20
TABLE C-2: CAD CELL RESISTANCE ........................21
TABLE C-3: R7184 TROUBLESHOOTING...................21
TABLE C-4: SYSTEM AND GENERAL
TROUBLESHOOTING....................................................24
AIR FILTER LOCATIONS...............................................27
REPAIR PART LIST – P3HMX14F10001 &
P3HMX20F12001............................................................28
REPAIR PART LIST – P3LBX12F08001A &
P3LBX14F12001A..........................................................29
REPAIR PART LIST – P2HMX12F08001.......................30
REPLACEMENT PART CONTACT INFORMATION......31
INSTALLATION
MANUAL
CONTENTS
Read this manual completely before beginning
installation.
Important: These instructions must be kept with
the furnace for future reference.

Questions and Answers:

York International P2HMX12F08001 Specifications

General IconGeneral
Model NumberP2HMX12F08001
CategoryFurnace
Blower MotorMulti-speed
Fuel TypeNatural Gas
Heating Capacity80000 BTU
Efficiency80% AFUE
StagesTwo-Stage

Summary

Introduction to the Furnace

Model and Capacity Overview

Details the various P2HMX, P3HMX, and P3LBX furnace models and their BTU/Hr. capacities.

Heat Loss Calculation Guidelines

Unit Location and Clearance

Horizontal Furnace Installation

Non-Suspended Installation Requirements

Suspended Installation Procedures

Air Conditioning Integration

Combustion Air Requirements

Chimney Venting Requirements

Draft Regulator Control System

Oil Tank Installation Guidelines

Piping Installation Guidelines

Electrical Connections

Circulating Air Blower Operation

Blower Speed Adjustment and Wiring

Explains how to adjust blower speed and wiring for direct drive motors.

Blower Safety Precautions

Details critical safety warnings regarding power and motor connections.

Heating Blower Off Delay Settings

Describes how to adjust the fan off delay timer using dip switches.

Oil Burner Assembly and Setup

Burner Alignment and Initial Setup

Emphasizes checking burner alignment and performing initial setup procedures.

Oil Burner Nozzle Selection

Burner Electrode Adjustment

Oil Burner Set-up Procedures

Pre-Setup Preparations

Outlines necessary preparations before setting up the oil burner, including test ports.

Furnace Installation Set-Up

Maintenance and Service

Routine and Annual Servicing

Covers both homeowner routine checks and contractor annual servicing procedures.

Furnace Operation and Safety

Details operating instructions, including lighting/shutdown, and critical safety warnings.

General Dimensions – P*HMX Models

General Dimensions – P3LBX Models

Appendix B: Wiring Diagram

Wiring Diagram Symbols and Legend

Explains the symbols and abbreviations used in the wiring diagram.

Wiring Notes and Connections

Continuous Fan Operation Setup

Explains how to set up continuous fan operation using the ST9103 EFT.

Thermostat and Accessory Wiring

Details thermostat connections and accessory power provisions.

Electrical Safety During Wiring

Warns about turning off power before servicing or altering furnace wiring.

R7184 Detailed Sequence of Operation

R7184 LED Diagnostic Light Functions

Troubleshooting Guide

Preliminary Troubleshooting Steps

Outlines initial checks and precautions before troubleshooting the R7184 control.

Electrical Shock Hazard Warning

Warns about the risks of electrical shock during troubleshooting and emphasizes safety.

System and General Troubleshooting

Furnace Will Not Start Troubleshooting

Addresses common causes and remedies when the furnace fails to start.

Air Filter Locations

Repair Parts List – P3HMX14F10001 & P3HMX20F12001

Repair Parts List – P3LBX12F08001A & P3LBX14F12001A

Repair Parts List – P2HMX12F08001

Replacement Part Contact Information

Notes