YORK® CEILING AND INLINE CENTRIFUGAL FANS, CI-SERIES
16
Model
Hemispherical
Sonesat
0.0”Ps(4)
Spherical
Sonesat
0.0”Ps(5)
CFMatStaticPressure(Ps-InchesofH
2
O)
Volts Watts
Nominal
RPM
Duct
Dia.
Est.
Shipping
Wt.(Lbs.)
0.000 .100 .125 .250 .375 .500
CI1 3.4
2.3
56 51 50 46 41 32 120 55 1700 3" 5
CIL1 1.9
1.8
62 51 49 32 9 - 120 30 1070 4" 7
CIL2 4.0
3.4
97 87 84 69 50 19 120 50 1380 4" 8
(1) Performance shown is for installation type B - Free inlet, ducted outlet.
(2) Performance ratings include the effects of inlet grille and backdraft damper in the airstream.
(3) Speed (RPM) shown is nominal. Performance is based on actual speed of test.
(4) The sound ratings shown are loudness values in fan sones at 5ft. (1.5m) in a hemispherical free eld calculated per AMCA Standard 301
(5) The spherical sones values are calculated to represent sound in a spherical free eld at 5 ft. (1.5m) per Annex B of AMCA 311.
(6) Values shown are for installation Type B: free inlet fan sone levels.
CI1 | LOW FLOW CEILING FAN
7 1/2”
7 1/2”
3 5/8”
9 1/4”
9”
3/8”
7 1/2”
7 1/2”
3 5/8”
9 1/4”
9”
3/8”
56 CFM @ 0.0” Ps.
Quiet-designed durable blower wheels.
Torsion spring grille mounting; no tools needed.
Compact housings t easily between wall studs.
Double strength steel mounting anges with keyhole
lots for fast, sturdy installation.
UL507 Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit.
AMCA Air and Sound certied.
CIL1 & CIL2 | CEILING FANS WITH LIGHT
62 CFM @ 0.0” Ps – Model CIL1
97 CFM @ 0.0” Ps – Model CIL2
100 watt lighting (bulb not included)
Totally enclosed low RPM motor with sealed bearings.
Centrifugal blower wheel.
White molded polymeric grille with unbreakable light lens.
Plug-in receptacles for fan and light.
Rugged steel housing with built-in mounting brackets.
4” Polymeric duct connector.
Durable damper eliminates backdrafts; no metallic clatter.
UL507 Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit.
AMCA Air and Sound certied.
8”
8 1/4”
5 3/4”
10 5/8”
11 1/8”
2”
8”
8 1/4”
5 3/4”
10 5/8”
11 1/8”
2”