567175-YTG-E-0512
14 Johnson Controls Unitary Products
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
CZF04813(C)
(Y*LC/T*8V/T*LV)*C20 21 FC/PC60C 1625 45.0 33.0 14.50 12.00
(Y*9C/T*9V)*C16 21 FC/PC60C 1590 44.5 32.8 14.25 12.00
(Y*9C/T*9V)*C20 21 FC/PC60C 1655 44.5 32.8 14.25 12.00
(Y*9C/T*9V)*D20 24 FC/MC/PC60D 1615 45.0 33.0 14.50 12.00
(Y*LC/T*8V/T*LV)*C16 21 FC/MC/PC60D 1600 45.0 32.8 14.50 12.00
(Y*LC/T*8V/T*LV)*C20 21 FC/MC/PC60D 1625 45.0 33.0 14.50 12.00
(Y*9C/T*9V)*C16 21 FC/MC/PC60D 1590 44.5 32.8 14.25 12.00
(Y*9C/T*9V)*C20 21 FC/MC/PC60D 1655 44.5 32.8 14.25 12.00
(Y*LC/T*8V/T*LV)*C16 21 FC/MC62D 1635 45.5 33.6 14.75 12.25
(Y*LC/T*8V/T*LV)*C20 21 FC/MC62D 1620 45.5 33.6 15.00 12.50
(Y*9C/T*9V)*C16 21 FC/MC62D 1590 45.0 33.4 14.75 12.25
(Y*9C/T*9V)*C20 21 FC/MC62D 1655 45.0 33.4 14.25 12.00
(Y*9C/T*9V)*D20 24 FC/MC62D 1630 45.0 33.4 14.50 12.25
(Y*LC/T*8V/T*LV)*C16 21 HD48 1615 44.5 32.6 13.75 12.00
(Y*LC/T*8V/T*LV)*C20 21 HD48 1640 44.5 32.6 13.75 12.00
(Y*LC/T*8V/T*LV)*C16 21 HD60 1625 45.5 33.6 14.75 12.25
(Y*LC/T*8V/T*LV)*C20 21 HD60 1605 45.5 33.6 15.00 12.50
(Y*9C/T*9V)*C16 21 HD60 1590 45.0 33.4 14.50 12.00
(Y*9C/T*9V)*C20 21 HD60 1655 45.0 33.4 14.50 12.00
(Y*9C/T*9V)*D20 24 HD60 1615 45.0 33.4 14.50 12.25
(Y*LC/T*8V/T*LV)*C20 21 UC60C 1605 44.5 32.6 14.75 12.25
(Y*LC/T*8V/T*LV)*C16 21 FC64D 1420 46.0 33.6 15.75 13.00
(Y*LC/T*8V/T*LV)*C20 21 FC64D 1410 46.0 33.6 16.00 13.00
(Y*9C/T*9V)*C16 21 FC64D 1445 46.0 33.4 15.25 12.50
(Y*9C/T*9V)*C20 21 FC64D 1445 46.0 33.6 15.50 12.75
(Y*9C/T*9V)*D20 24 FC64D 1455 46.0 33.8 15.75 13.00
CZF06013(C)
T*(8,L)X*C20 21 FC/PC60C 1595 52.0 35.3 15.00 12.75
T*9X*C20 21 FC/PC60C 1625 52.0 35.5 15.00 12.75
T*(8,L)X*C20 21 FC/MC/PC60D 1690 52.0 36.1 15.25 13.00
T*9X*C20 21 FC/MC/PC60D 1645 52.0 35.5 15.25 12.75
T*9X*D20 24 FC/MC/PC60D 1730 52.5 36.5 15.50 13.00
T*(8,L)X*C20 21 FC/MC62D 1665 53.0 36.9 15.50 13.25
T*9X*C20 21 FC/MC62D 1595 53.0 36.9 15.50 13.00
T*9X*D20 24 FC/MC62D 1645 53.0 36.7 15.25 13.00
T*(8,L)X*C20 21 FC64D 1665 54.5 38.5 16.00 13.25
T*9X*D20 24 FC64D 1645 54.0 38.0 16.00 13.25
(Y*LC/T*8V/T*LV)*C20 21 FC/MC62D 1600 52.5 36.5 15.00 12.50
(Y*9C/T*9V)*C20 21 FC/MC62D 1655 52.5 36.5 14.75 12.50
(Y*9C/T*9V)*D20 24 FC/MC62D 1630 52.5 36.5 15.00 12.75
(Y*LC/T*8V/T*LV)*C20 21 FC64D 1855 54.5 39.0 15.25 12.75
(Y*9C/T*9V)*C20 21 FC64D 1655 54.0 37.8 15.25 12.75
(Y*9C/T*9V)*D20 24 FC64D 1630 54.0 37.6 15.25 12.75
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.
COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE
COIL
MODEL
1
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
16 SEER AC WITH HIGH EFFICIENCY MOTOR FURNACES
2