TECHNICAL GUIDE
STELLAR PLUS
TM
SPLIT-SYSTEM AIR CONDITIONERS
12 SEER
MODELS:
H4DH018 THRU 060
(1.5 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications
are subject to change without notice.
V
isit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
LISTED
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
Certification applies only
when the complete
system is listed
with ARI.
R
N
E
M
P
I
U
Q
E
T
Y
R
A
T
I
N
U
0
1
2
A
R
I
R
A
D
N
A
T
S
D
I
S
N
O
T
C
E
S
F
O
C
C
I
F
I
T
R
E
N
O
I
T
A
H
T
I
W
C
G
N
I
Y
L
P
M
O
S
A
I
R
A
O
T
D
E
I
F
I
T
R
E
C
R
E
R
U
T
C
A
F
U
N
A
M
C
-
G
N
I
N
O
I
T
I
D
N
O
R
I
A
036-21020-003 Rev. C (0203)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The HDH Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom-
matched with one of York’s complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
application to provide a complete system. Electric heaters are
available if required. Add-On coils are available for use with
upflow, downflow or horizontal furnaces.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur.
DURABLE FINISH - Cabinet is made of powder painted
steel over pre-primered steel. The pre-treated galvanized
steel provides a better paint to steel bond, which resists
corrosion and rust creep. Special primer formulas and
automotive quality finish insure less fading when exposed
to sunlight.
LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Hard start kits are available for non-scroll models. All
units contain enough refrigerant for a matching indoor coil
and 15 feet of interconnecting piping. The small base
dimension means less space is required on the ground or
roof.
TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections and a single panel covering the electrical controls
make servicing easy.
SECURED SERVICE VALVES -Provided on both the liq-
uid and vapor sweat connections for ease of evacuating
and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the York STELLAR PLUS H4DH018 THRU 060 and is the answer not in the manual?

York STELLAR PLUS H4DH018 THRU 060 Specifications

General IconGeneral
BrandYork
ModelSTELLAR PLUS H4DH018 THRU 060
CategoryAir Conditioner
LanguageEnglish

Summary

Technical Guide Overview

Stellar Plus Split-System Air Conditioners (12 SEER)

Overview of Stellar Plus 12 SEER split-system air conditioners.

Model Series H4DH018-060

Details models H4DH018 through H4DH060, covering 1.5 to 5 nominal tons.

Product Description

HDH Series Condensing Unit

Describes the outdoor unit of the HDH Series air conditioning system.

Warranty Information

5-Year Limited Parts Warranty

States the warranty period for limited parts.

10-Year Limited Compressor Warranty

States the warranty period for the limited compressor.

Product Features

Quality Condenser Coils

Details the construction of the condenser coils.

Coil Protection Measures

Explains the protection applied to the coils.

Protected Compressor Design

Describes the internal protection for the compressor.

Durable Cabinet Finish

Highlights the cabinet's powder-painted steel finish.

Ease of Installation & Cost Savings

Notes features that reduce installation time and cost.

Top Discharge Airflow

Explains the upward direction of discharged air.

Reduced Operating Sound

Details features for low operational noise levels.

Low Maintenance Requirements

Mentions features requiring minimal maintenance.

Accessible Service Points

Describes easy access for servicing.

Secured Service Valves

Notes the presence of secured service valves.

Safety & Certification Listings

Confirms U.L. and C.U.L. listing for outdoor application.

Physical and Electrical Data

Unit Voltage and Electrical Specifications

Details voltage, ampacity, and breaker requirements.

Compressor and Fan Motor Specifications

Lists compressor type, amps, and fan motor details.

Coil Dimensions and Refrigerant Lines

Provides coil dimensions and refrigerant line sizes.

Unit Dimensions and Operating Weight

Shows overall unit dimensions and operating weight.

Refrigerant Charge and Orifice Sizing

R-22 Charge and Orifice Size Tables

Tables for R-22 charge and orifice size for matched systems.

Refrigerant Charge Adjustment Procedures

Instructions for verifying and adjusting system refrigerant charge.

Cooling Capacity with Air Handler Coils

1 PH 12 SEER AC / N1AH + G2FD Coils

Cooling performance for N1AH air handlers with G2FD coils.

1 PH 12 SEER AC / N1VS Variable Speed Coils

Cooling performance for N1VS variable speed air handlers with coils.

1 PH 12 SEER AC / F2RP/RC/FP/FC/FV Coils

Cooling performance for F2RP/RC/FP/FC/FV fan coil units.

Cooling Capacity with Furnaces and Coils

Furnace & Coil Combinations (G1FA/G1HD/G2FD)

Cooling capacity data for various furnace and coil matches.

Cooling Capacity with Furnaces and Coils (Continued)

Extended Furnace & Coil Combinations

Additional cooling capacity data for furnace and coil pairings.

Cooling Capacity with Variable Speed Furnaces

1 PH 12 SEER AC / Variable Speed Furnace Options

Cooling capacity for 12 SEER units with variable speed furnaces.

Cooling Capacity with Variable Speed Furnaces (Continued)

H4DH036S06 & H4DH042S06 Variable Speed Cooling

Cooling performance data for specific models with variable speed furnaces.

Cooling Capacity with Variable Speed Furnaces (Continued)

H4DH048S06 & H4DH060S06 Variable Speed Cooling

Cooling performance data for H4DH048S06/H4DH060S06 with variable speed furnaces.

Cooling Performance Data

Performance by Suction Conditions

Tables showing performance at various suction pressures and temperatures.

Unit Sound Ratings

Decibel ratings for different outdoor unit models.

Installation and Wiring

Outdoor Unit Placement and Clearances

Guidelines for installing the outdoor condensing unit.

Typical Single Phase Field Wiring

Illustrates field wiring for 1-phase systems.

Detailed Cooling Performance Data

H4DH018S06 with G1FA024S14,17 Coil Performance

Detailed performance data for H4DH018S06 and G1FA024S14,17 coil.

Performance Adjustment Multipliers (General)

Factors for adjusting performance with other indoor sections.

Detailed Cooling Performance Data

H4DH024S06 with G1FA024S14,17 Coil Performance

Detailed performance data for H4DH024S06 and G1FA024S14,17 coil.

Performance Adjustment Multipliers (General)

Factors for adjusting performance with other indoor sections.

Detailed Cooling Performance Data

H4DH030S06 with G1FA036S17,21 Coil Performance

Detailed performance data for H4DH030S06 and G1FA036S17,21 coil.

Performance Adjustment Multipliers (General)

Factors for adjusting performance with other indoor sections.

Detailed Cooling Performance Data

H4DH036S06 with G1FA036S17,21 Coil Performance

Detailed performance data for H4DH036S06 and G1FA036S17,21 coil.

Performance Adjustment Multipliers (General)

Factors for adjusting performance with other indoor sections.

Detailed Cooling Performance Data

H4DH042S06 with G1FA048S21 Coil Performance

Detailed performance data for H4DH042S06 and G1FA048S21 coil.

Performance Adjustment Multipliers (General)

Factors for adjusting performance with other indoor sections.

Detailed Cooling Performance Data

H4DH048S06 with G1FA048S21 Coil Performance

Detailed performance data for H4DH048S06 and G1FA048S21 coil.

Performance Adjustment Multipliers (General)

Factors for adjusting performance with other indoor sections.

Detailed Cooling Performance Data

H4DH060S06 with G1FA060S21,24 Coil Performance

Detailed performance data for H4DH060S06 and G1FA060S21,24 coil.

Performance Adjustment Multipliers (General)

Factors for adjusting performance with other indoor sections.

Matching Indoor Components

Add-On Coils for Furnace Applications

Visual guide to add-on coils for furnace systems.

Air Handlers for Non-Furnace Applications

Visual guide to air handlers for non-furnace systems.

Document Notes and Revision

Revision and Copyright Information

Contains copyright, revision, and superseding details for the manual.

Related product manuals