036-21318-002 Rev. A (0106)
Unitary Products Group 21
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. EBBA-F018S
EVAPORATOR COIL MODEL NO. F2RP/F2FP018
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
500 650 800
MBTUH
KW C.O.P. MBTUH K C.O.P. MBTUH KW C.O.P.
60
60 21.11.703.6621.81.703.7622.01.574.11
70 20.11.733.4221.01.743.5321.31.623.86
80 19.01.763.1620.01.793.2820.61.683.60
47
60 17.81.623.2218.01.643.2118.11.543.43
70 16.51.672.9117.01.692.9617.31.583.21
80 15.21.722.6016.01.742.7016.41.632.97
40
60 13.61.303.0515.51.602.8416.11.503.15
70 12.61.492.4914.51.642.5914.41.542.73
80 11.6 1.98 1.73 13.5 1.70 2.34 12.7 1.87 2.00
30
60 13.11.542.5013.51.552.5513.21.422.72
70 12.01.582.2212.41.602.2812.51.492.46
80 10.8 1.62 1.94 11.4 1.66 2.01 11.8 1.57 2.21
17
60 9.7 1.431.9910.21.452.0610.41.372.21
70 8.6 1.51 1.66 9.1 1.50 1.78 9.3 1.46 1.88
80 7.5 1.61 1.36 8.0 1.56 1.50 8.3 1.55 1.58
10
60 8.1 1.35 1.77 8.6 1.38 1.82 8.9 1.30 2.01
70 6.9 1.39 1.46 7.5 1.43 1.53 7.9 1.35 1.71
80 5.6 1.43 1.16 6.3 1.48 1.25 6.9 1.41 1.43
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
MBH KW COP
N1AHB0806 G2FD024(S,H)14,17 1.00 0.98 1.02
F2RP/F2FP024 1.00 0.98 1.01
G2FD024(S,H)14,17 1.00 0.98 1.02
G1HD024 1.01 0.98 1.03
G1NA030S17H 1.01 1.01 1.00
G1NA030S21B 1.01 1.01 1.00
G1UA024S14,17 0.99 0.99 1.00
G1FA024S14,17 0.99 0.99 1.00
G1UA030S14 1.00 0.98 1.02
G1FA030S14 1.00 0.98 1.02