036-21318-002 Rev. A (0106)
Unitary Products Group 25
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO EABA-F042S
EVAPORATOR COIL MODEL NO F2RP/F2FP042
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1200 1400 1600
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 48.53.394.2147.43.304.2246.13.254.16
70 46.63.683.7245.63.573.7544.93.533.74
80 46.64.113.3345.83.993.3745.63.923.41
47
60 40.83.393.5440.53.333.5739.73.323.52
70 39.33.663.1539.03.603.1838.63.583.17
80 39.04.062.8238.83.992.8638.73.942.88
40
60 37.1 3.48 3.13 36.4 3.45 3.11 36.3 3.43 3.11
70 35.33.792.7334.83.752.7334.93.722.75
80 34.44.162.4334.24.102.4534.44.072.48
30
60 31.8 3.13 2.99 31.8 3.11 3.00 31.8 3.12 3.00
70 30.53.452.6030.13.402.6030.43.402.63
80 29.83.752.3429.03.672.3229.73.672.38
17
60 23.7 3.09 2.25 24.0 3.11 2.27 24.3 3.12 2.29
70 22.73.312.0123.13.322.0523.33.332.06
80 21.63.551.7922.23.551.8422.43.561.85
10
60 19.82.912.0020.12.932.0120.42.972.02
70 18.83.091.7919.33.121.8219.53.151.82
80 17.43.241.5818.23.271.6318.33.291.64
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
MBH KW COP
N1AHC1606 G2FD048(S,H)21 1.00 0.99 1.01
F2FP048 1.01 0.98 1.04
G2FD042(S,H)21 0.99 1.01 0.98
G2FD046(S,H)17 0.99 1.00 0.98
G2FD048(S,H)21,24 1.00 0.99 1.01
G2FD060(S,H)24 1.00 1.02 0.98
G1HD048 0.99 1.00 0.98
G1NA048S21D 1.02 1.04 0.99
G1UA048S21 0.99 1.00 0.98
G1FA048S21 0.99 1.00 0.98