COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
WITH TXV
3
EER
TOTAL SENS.
1 PH 10 SEER HP WITH N-AH / G2FD
EBBA-F018S N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 650 17.8 12.8 10.10 - 8.95
EBBA-F024S N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 840 22.6 16.2 10.00 - 9.30
EABA-F030S N1AHB1206 5,8,10,15,19 17 G2FD030(S,H)17 1000 28.0 19.6 10.00 - 9.10
EABA-F036S N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1250 33.6 24.9 10.00 - 8.80
EABA-F042S N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1400 40.0 29.6 10.10 - 9.15
EBBA-F048S
N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1600 45.5 33.7 10.00 - 9.45
N1AHD2006 8,10,15,20,25,30 24 G2FD048(S,H)24 1600 45.5 33.7 10.00 - 9.45
N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1600 46.5 34.4 10.20 - 9.60
EABA-F060S N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1800 54.5 39.2 - 10.00 8.95
3 PH 10 SEER HP WITH N-AH / G2FD
EABA-(T,W)036S N1AHC1646 10,15 21 G2FD042(S,H)21 1250 34.2 25.3 10.00 - 8.95
EBBA-(T,W)048S)
N1AHC1646 10,15 21 G2FD048(S,H)21 1600 45.5 33.7 10.00 - 9.45
N1AHD2046 10,15,29 24 G2FD048(S,H)24 1600 45.5 33.7 10.00 - 9.45
EABA-(T,W)060S N1AHD2046 10,15,29 24 G2FD060(S,H)24 1700 57.0 41.0 10.00 - 9.80
1 PH 10 SEER HP / F2RP / RC / FP / FC
EBBA-F018S
F2RP/FP018 2,5,8 18 - 600 17.0 12.3 10.00 - 8.90
F2RP/FP024 5,8,10 18 - 650 17.8 12.4 10.00 - 8.95
EBBA-F024S
F2RP/FP024 5,8,10 18 - 800 22.0 16.5 10.00 - 9.30
F2RP/FP030 5,8,10,15 18 - 840 22.6 16.8 10.00 - 9.40
EABA-F030S
F2RP/FP030 5,8,10,15 18 - 1000 28.4 21.0 10.00 - 9.20
F2RP/FP036 5,8,10,15,19 21 - 1000 29.0 20.9 10.00 - 9.40
EABA-F036S
F2RP/FP036 5,8,10,15,19 21 - 1250 34.0 24.9 10.00 - 9.00
F2RP/FP042 5,8,10,15 21 - 1250 34.0 24.9 10.00 - 9.00
EABA-F042S
F2RP/FP042 5,8,10,15 21 - 1400 39.0 28.4 10.00 - 8.90
F2FP048 5,8,10,15,20,25 24 - 1400 39.5 28.8 10.00 - 9.15
EBBA-F048S
F2FP048 5,8,10,15,20,25 24 - 1600 45.0 33.5 10.00 - 9.40
F2FP060 5,8,10,15,20,25 24 - 1600 46.5 34.4 10.00 - 9.60
EABA-F060S F2FP060 5,8,10,15,20,25 24 - 1850 54.0 40.5 - 10.00 8.60
3 PH 10 SEER HP / F2RP / RC / FP / FC
4,5
EABA-(T,W)036S)
F2RP/FP036 5,8,10,15,19 21 - 1250 34.0 24.9 10.00 - 9.00
F2RP/FP042 5,8,10,15 21 - 1250 34.0 25.6 10.00 - 9.00
EBBA-(T,W)048S
F2FP048 5,8,10,15,20,25 24 - 1600 45.0 33.5 10.00 - 9.40
F2FP060 5,8,10,15,20,25 24 - 1600 46.5 34.4 10.00 - 9.60
EABA-(T,W)060S) F2FP060 5,8,10,15,20,25 24 - 1700 56.0 40.0 10.00 - 9.40
3 PH 10 SEER HP / FHP
EABA-(T,W)090S FCEH090 10,16,26,36 25-1/8 - 3000 91.0 87.4 - - 9.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input
in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard.