036-21318-002 Rev. A (0106)
Unitary Products Group 9
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric
power input during the same period.
— = Not Applicable.
ACCESSORIES
Refer to Price Manual for specific model numbers.
Start Assist Kit (2SA067*)
Blower Time Delay - Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.
Hard Start Kits - Provides required starting torque for use
with Thermal Expansion Valve Kit.
Low Temperature Cutout (2LT06700224) - Prevents heat
pump operation below -10°F ambient temperature.
Compressor Blanket - Designed to further reduce the nor-
mal operating sound.
Add-on Fossil Fuel Control - Interface controls for use with
gas, oil furnaces and the heat pump system are available.
Thermal Expansion Valve Kit - 1TV0700 Series TXV kit
used to improve system performance.
Outdoor Thermostat (2TD06700124) - Provides additional
staging of supplemental electric heat.
Room Thermostats - A wide selection of matching
thermostats is available to provide features required for
any installation.
2H/1C, manual change-over electronic non-programmable
thermostat.
3H/2C, non-programmable digital thermostat.
3H/2C, auto/manual changeover, electronic programmable,
7-day, hardwire thermostat.
* For the most current accessory information, refer to the
price book or consult factroy.
SOUND RATINGS*
*Rated in accordance with ARI Standard 270.
All dimensions are in inches. They are subject to change without
notice. Certified dimensions will be provided upon request.
EBBA-(T,W)048S
G2FD048(S,H)21,24 47.0 3.02 31.2 2.32 7.5 21.0 3.56 26.1 3.75 31.2 3.94 36.3 4.13 40.1 4.32 47.0 4.56 54.1 4.59
G1NA048S21D 47.0 2.96 31.2 2.30 7.5 20.7 3.52 25.9 3.75 31.2 3.98 35.2 4.13 39.2 4.29 47.0 4.65 52.3 4.88
G1UA048S21 47.03.0031.22.30 7.5 20.93.6026.13.7931.23.9836.34.1642.04.3947.04.5954.04.61
G1FA048S21 47.0 3.00 31.2 2.30 7.5 20.9 3.60 26.1 3.79 31.2 3.98 36.3 4.16 42.0 4.39 47.0 4.59 54.0 4.61
EABA-F060S
G2FD060(S,H)24 56.5 3.10 37.0 2.30 7.5 24.1 4.30 30.6 4.51 37.0 4.71 43.4 4.92 48.2 5.09 56.5 5.34 65.9 5.59
G1HD060 57.0 3.10 37.0 2.30 7.5 24.0 4.30 30.5 4.51 37.0 4.71 43.5 4.92 48.3 5.10 57.0 5.37 66.1 5.55
G1NA060S24T 58.03.1637.02.38 7.5 23.04.0130.04.2837.04.5640.94.6944.84.8258.05.3865.05.65
G1UA060S21,24 56.5 3.10 37.0 2.30 7.5 24.1 4.30 30.6 4.51 37.0 4.71 43.4 4.92 48.2 5.09 56.5 5.34 65.9 5.59
G1FA060S21,24 56.53.1037.02.30 7.5 24.14.3030.64.5137.04.7143.44.9248.25.0956.55.3465.95.59
EABA-(T,W)060S
G2FD060(S,H)24 58.0 3.20 38.5 2.40 7.7 25.5 4.29 32.0 4.50 3.9 4.70 42.1 4.91 45.7 5.11 58.0 5.31 64.5 5.51
G1UA060S24 58.0 3.20 38.5 2.40 7.7 25.5 4.29 32.0 4.50 3.9 4.70 42.1 4.91 45.7 5.11 58.0 5.31 64.5 5.51
G1FA060S24 58.0 3.20 38.5 2.40 7.7 25.5 4.29 32.0 4.50 3.9 4.70 42.1 4.91 45.7 5.11 58.0 5.31 64.5 5.51
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric
heat operation.
3. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur.
HEATING PERFORMANCE - With Furnace Coils (Continued)
UNIT
MODEL*
COIL
1
MODEL
ARI HEATING
2
OUTDOOR TEMP
3
47°F17°F
HSP
F
-3°F7°F17°F27°F37°F47°F57°F
MBH COP MBH COP STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW
UNIT
MODEL
SOUND RATINGS
DECIBELS
018 80
024 80
030 80
036 82
042 82
048 77
060 82
DIMENSIONS - 1 PHASE
UNIT
MODEL
DIMENSIONS
(INCHES)
REFRIGERANT
CONNECTION
LINE SIZE
A
1
1. Including fan guard.
B C Liquid Vapor
018 19 35 23
3/8”
3/4”
024 25 35 23
030 25 35 23
036 25 35 23
042 27 37 27
048 33 37 27
7/8”
060 39 37 27
DIMENSIONS - 3 PHASE
UNIT
MODEL
DIMENSIONS
(INCHES)
REFRIGERANT
CONNECTION
LINE SIZE
A
1
1. Including fan guard.
B C Liquid Vapor
036 25 35 23
3/8”
3/4”
048 33 37 27 7/8”
060 26 43 32 7/8”
090 32 43 32 1/2” 1-1/8”
C
B
A