COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL
ELECTRIC
HEAT KW
2
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
EER
TOTAL SENS.
1 and 3 Phase 10 SEER HP / N1AH / G2FD
E4FD018 N1AHB08 2,5,7.5,10 17 G2FD024(S,H)17 650 18.4 13.8 11.00 --- 9.10
E4FD024
N1AHB08 2,5,7.5,10 17 G2FD024(S,H)17 800 23.0 17.3 10.45 --- 9.15
N1AHB08 5,7.5,10,15,18 17 G2FD030(S,H)17 800 23.4 17.6 10.50 --- 9.40
E4FD030
N1AHB12 5,7.5,10,15,18 17 G2FD030(S,H)17 1000 29.0 21.8 10.50 --- 9.40
N1AHB12 5,7.5,10,15,18 17 G2FD036(S,H)17 1025 29.4 22.1 11.00 --- 9.40
E4FD036
N1AHB12 5,7.5,10,15,18 17 G2FD036(S,H)17 1220 35.0 26.3 10.00 --- 9.20
N1AHB12 5,7.5,10,15,18 17 G2FD042(S,H)17 1220 35.4 26.6 10.20 --- 9.15
N1AHB12 5,7.5,10,15,18 17 G2FD046(S,H)17 1220 35.4 26.6 10.20 --- 9.15
E4FD042
N1AHC16 5,7.5,10,15,20 21 G2FD042(S,H)21 1400 40.5 30.0 10.00 --- 9.15
N1AHC16 5,7.5,10,15,20 21 G2FD048(S,H)21 1425 41.5 30.7 10.10 --- 9.25
E4FD048
N1AHC16 5,7.5,10,15,20,25,30 21 G2FD048(S,H)21 1600 45.5 33.7 10.50 --- 9.40
N1AHD20 5,7.5,10,15,20,25,30 24 G2FD048(S,H)24 1600 45.5 33.7 10.50 --- 9.40
N1AHD20 5,7.5,10,15,20,25,30 24 G2FD060(S,H)24 1625 47.0 34.8 10.80 --- 9.65
E4FD060 N1AHD20 5,7.5,10,15,20,25,30 24 G2FD060(S,H)24 1800 59.0 44.0 11.00 --- 9.90
1 and 3 Phase 10 SEER HP / N1VS / G2FD
E4FD018 N1VSB12 5,7.5,10,15,18 17 G2FD024(S,H)17 650 19.0 14.3 12.00 --- 10.30
E4FD024
N1VSB12 5,7.5,10,15,18 17 G2FD024(S,H)17 800 23.6 17.7 11.70 --- 10.20
N1VSB12 5,7.5,10,15,18 17 G2FD030(S,H)17 850 24.0 18.0 11.80 --- 10.65
E4FD030
N1VSB12 5,7.5,10,15,18 17 G2FD036(S,H)17 1025 30.0 22.5 11.60 --- 9.30
N1VSB12 5,7.5,10,15,18 17 G2FD030(S,H)17 1025 29.0 21.8 11.30 --- 9.40
E4FD036
N1VSB12 5,7.5,10,15,18 17 G2FD036(S,H)17 1200 35.6 26.7 10.80 --- 9.50
N1VSB16 5,7.5,10,15,20 17 G2FD036(S,H)21 1200 35.6 26.7 11.00 --- 9.70
N1VSB12 5,7.5,10,15,18 17 G2FD046(S,H)17 1200 36.2 27.2 11.00 --- 9.80
N1VSC16 5,7.5,10,15,20 21 G2FD042(S,H)21 1225 36.2 27.2 11.20 --- 10.00
E4FD042 N1VSC16 5,7.5,10,15,20 21 G2FD048(S,H)21 1425 42.0 31.1 11.00 --- 10.00
E4FD048
N1VSC16 5,7.5,10,15,20 21 G2FD048(S,H)21 1600 46.0 34.0 11.00 --- 10.00
N1VSD20 7.5,10,15,20,25,30 24 G2FD060(S,H)24 1625 48.0 35.5 12.00 --- 10.60
E4FD060 N1VSD20 7.5,10,15,20,25,30 24 G2FD060(S,H)24 1800 60.0 45.0 11.50 --- 11.20
1 and 3 Phase 10 SEER HP / F2RP / FP / FV
4,5
E4FD018
F2RP/F2FP018 2,5,8 18 --- 650 17.5 13.0 10.70 --- 9.80
F2RP/F2FP024 5,8,10,(10),(15) 18 --- 650 18.8 14.0 10.50 --- 10.45
E4FD024
F2RP/F2FP024 5,8,10,(10),(15) 18 --- 800 22.6 17.0 10.40 --- 9.40
F2RP/F2FP030 5,8,10,15,(10),(15) 18 --- 800 23.2 17.4 10.70 --- 9.50
E4FD030
F2RP/F2FP030 5,8,10,15,(10),(15) 18 --- 1050 29.0 21.8 10.50 --- 9.3
F2RP/F2FP036 5,8,10,15,(10),(15) 18 --- 1050 29.4 22.1 11.00 --- 9.4
E4FD036
F2RP/F2FP036 5,8,10,15,(10),(15) 18 --- 1200 34.2 25.7 10.00 --- 8.90
F2RP/F2FP042 5,8,10,15,(10),(15) 21 --- 1200 35.0 26.3 10.20 --- 9.20
E4FD042
F2RP/F2FP042 5,8,10,15,(10),(15) 21 --- 1500 40.5 30.0 10.00 --- 9.40
F2FP048 10,15, 20, 25, (10),(15) 24 --- 1450 41.5 30.7 10.30 --- 9.65
E4FD048
F2FP048 10,15, 20, 25, (10),(15) 24 --- 1650 46.0 34.0 10.00 --- 9.40
E4FD060
F2FP060 10,15, 20, 25, (10),(15) 24 --- 1800 57.5 43.1 10.00 --- 9.60
F2FV060 10,15, 20, 25, (10),(15) 24 --- 1800 59.0 44.2 11.00 --- 10.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2FP/F2FV air handlers have B.O.D (Blower on Delay) standard.