5146416-YTG-B-1215
24 Johnson Controls Unitary Products
YCD36B21(H,S) TM8X080B12MP11 17.5 CF/CM/CU36B 1000 35.0 23.4 13.75 11.75
YCD36B21(H,S) TM8X080B12MP11 17.5 CF42B 1000 35.2 23.8 13.75 11.75
YCD36B21(H,S) TM8X080C16MP11 21.0 CF/CM/CU36C 1050 35.4 24.4 13.75 11.75
YCD36B21(H,S) TM8X080C16MP11 21.0 CF/CM/CU36D 1075 35.4 24.6 14.00 12.00
YCD36B21(H,S) TM8X080C16MP11 21.0 CF/CM/CU42C 1050 35.4 24.6 14.00 12.00
YCD36B21(H,S) TM8X080C16MP11 21.0 CF/CM/CU42D 1075 35.6 25.0 14.00 12.00
YCD36B21(H,S) TM8X080C16MP11 21.0 CF/CM/CU48C 1225 36.0 26.2 13.75 11.75
YCD36B21(H,S) TM8X080C16MP11 21.0 CF/CM/CU48D 1075 35.6 24.8 14.00 12.00
YCD36B21(H,S) TM8X100C16MP11 21.0 CF/CM/CU36C 1050 35.4 24.4 13.75 11.75
YCD36B21(H,S) TM8X100C16MP11 21.0 CF/CM/CU36D 1075 35.4 24.6 14.00 12.00
YCD36B21(H,S) TM8X100C16MP11 21.0 CF/CM/CU42C 1050 35.4 24.6 14.00 12.00
YCD36B21(H,S) TM8X100C16MP11 21.0 CF/CM/CU42D 1075 35.6 25.0 14.00 12.00
YCD36B21(H,S) TM8X100C16MP11 21.0 CF/CM/CU48C 1225 36.0 26.2 13.75 11.75
YCD36B21(H,S) TM8X100C16MP11 21.0 CF/CM/CU48D 1075 35.6 24.8 14.00 12.00
YCD36B21(H,S) TM8X100C20MP11 21.0 CF/CM/CU36C 1300 35.8 27.0 13.75 11.75
YCD36B21(H,S) TM8X100C20MP11 21.0 CF/CM/CU36D 1300 36.0 27.0 13.75 11.75
YCD36B21(H,S) TM8X100C20MP11 21.0 CF/CM/CU42C 1075 35.6 25.0 14.00 12.00
YCD36B21(H,S) TM8X100C20MP11 21.0 CF/CM/CU42D 1100 35.8 25.2 14.25 12.25
YCD36B21(H,S) TM8X100C20MP11 21.0 CF/CM/CU48C 1275 36.0 26.8 13.75 11.75
YCD36B21(H,S) TM8X100C20MP11 21.0 CF/CM/CU48D 1200 35.8 26.0 13.75 11.75
YCD36B21(H,S) TM8X120C20MP11 21.0 CF/CM/CU36C 1300 35.8 27.0 13.75 11.75
YCD36B21(H,S) TM8X120C20MP11 21.0 CF/CM/CU36D 1300 36.0 27.0 13.75 11.75
YCD36B21(H,S) TM8X120C20MP11 21.0 CF/CM/CU42C 1075 35.6 25.0 14.00 12.00
YCD36B21(H,S) TM8X120C20MP11 21.0 CF/CM/CU42D 1100 35.8 25.2 14.25 12.25
YCD36B21(H,S) TM8X120C20MP11 21.0 CF/CM/CU48C 1275 36.0 26.8 13.75 11.75
YCD36B21(H,S) TM8X120C20MP11 21.0 CF/CM/CU48D 1200 35.8 26.0 13.75 11.75
YCD36B21(H,S) TM8Y060A12MP11 14.5 CF/CM36A 975 35.0 23.4 13.50 11.50
YCD36B21(H,S) TM8Y080B12MP11 17.5 CF/CM/CU36B 1000 35.0 23.4 13.75 11.75
YCD36B21(H,S) TM8Y080B12MP11 17.5 CF42B 1000 35.2 23.8 13.75 11.75
YCD36B21(H,S) TM8Y080C16MP11 21.0 CF/CM/CU36C 1050 35.4 24.4 13.75 11.75
YCD36B21(H,S) TM8Y080C16MP11 21.0 CF/CM/CU36D 1075 35.4 24.6 14.00 12.00
YCD36B21(H,S) TM8Y080C16MP11 21.0 CF/CM/CU42C 1050 35.4 24.6 14.00 12.00
YCD36B21(H,S) TM8Y080C16MP11 21.0 CF/CM/CU42D 1075 35.6 25.0 14.00 12.00
YCD36B21(H,S) TM8Y080C16MP11 21.0 CF/CM/CU48C 1225 36.0 26.2 13.75 11.75
YCD36B21(H,S) TM8Y080C16MP11 21.0 CF/CM/CU48D 1075 35.6 24.8 14.00 12.00
YCD36B21(H,S) TM8Y100C16MP11 21.0 CF/CM/CU36C 1050 35.4 24.4 13.75 11.75
YCD36B21(H,S) TM8Y100C16MP11 21.0 CF/CM/CU36D 1075 35.4 24.6 14.00 12.00
YCD36B21(H,S) TM8Y100C16MP11 21.0 CF/CM/CU42C 1050 35.4 24.6 14.00 12.00
YCD36B21(H,S) TM8Y100C16MP11 21.0 CF/CM/CU42D 1075 35.6 25.0 14.00 12.00
YCD36B21(H,S) TM8Y100C16MP11 21.0 CF/CM/CU48C 1225 36.0 26.2 13.75 11.75
YCD36B21(H,S) TM8Y100C16MP11 21.0 CF/CM/CU48D 1075 35.6 24.8 14.00 12.00
YCD36B21(H,S) TM8Y100C20MP11 21.0 CF/CM/CU36C 1300 35.8 27.0 13.75 11.75
YCD36B21(H,S) TM8Y100C20MP11 21.0 CF/CM/CU36D 1300 36.0 27.0 13.75 11.75
YCD36B21(H,S) TM8Y100C20MP11 21.0 CF/CM/CU42C 1075 35.6 25.0 14.00 12.00
YCD36B21(H,S) TM8Y100C20MP11 21.0 CF/CM/CU42D 1100 35.8 25.2 14.25 12.25
YCD36B21(H,S) TM8Y100C20MP11 21.0 CF/CM/CU48C 1275 36.0 26.8 13.75 11.75
YCD36B21(H,S) TM8Y100C20MP11 21.0 CF/CM/CU48D 1200 35.8 26.0 13.75 11.75
YCD36B21(H,S) TM8Y120C20MP11 21.0 CF/CM/CU36C 1300 35.8 27.0 13.75 11.75
YCD36B21(H,S) TM8Y120C20MP11 21.0 CF/CM/CU36D 1300 36.0 27.0 13.75 11.75
YCD36B21(H,S) TM8Y120C20MP11 21.0 CF/CM/CU42C 1075 35.6 25.0 14.00 12.00
YCD36B21(H,S) TM8Y120C20MP11 21.0 CF/CM/CU42D 1100 35.8 25.2 14.25 12.25
For notes see Page 40.
COOLING CAPACITY - With High Efficiency Motor Furnaces
1
(Continued)
UNIT
MODEL
FURNACE
COIL
MODEL
2
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.