York YCHD Series - Thermostat Chart - Single Stage AC with PSC Furnace

York YCHD Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
406905-UIM-C-1009
Johnson Controls Unitary Products 11
FIGURE 11: Thermostat Chart - Single Stage AC with PSC Furnace
AC 5E Single Stage Air Conditioner – Single Stage PSC Furnace
C
24 – Volt Common
Y
Compressor Contactor
SINGLE STAGE
AIR
CONDITIONER
SINGLE STAGE
AIR CONDITIONER
Y
Full Stage Compressor
G
Fan
*BP11C50124
*BN11C01124
*DP11C40124
*DN11C00124
THERMOSTAT
RH
24 – Volt Hot
(Heat XFMR)
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
Selection of GAS/ELEC
switch on thermostat
is not necessary
C
24 – Volt Common
Y
Full Stage Compressor
G
Fan
*BN11C00124
THERMOSTAT
RH
24 – Volt Hot
(Heat XFMR)
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
Thermostat Installer Setup
1-System Type-must be
set to 0
C
24 – Volt Common
Thermostat Installer Setup
15-Compressor Protection
must be set to 5
External Humidistat
(Optional)
Open on Humidity Rise
G8C
L(Y/M)8S
G*9F
G*(8/9)S
ID MODELS
(G/T)GLS
TG(8/9)S
LF8
GF(8/9)
C
24 – Volt Common
R
24 – Volt Hot
W
Full Stage Heat
SINGLE STAGE PSC
FURNACE
G
Fan
SINGLE STAGE
PSC
FURNACE
Other Part Numbers:
SAP = Legacy
265901 = 031-09166
1
1
24VAC Humidifier
(Optional)
2
Part Number:
S1-2HU16700124
2
Y/Y2
Full Stage Compressor