4
Notices for use
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't
arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within
2 mins):
1. Heating starts. 2.After Auto Defrost finished. 3.Heating under the low temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle breeze, and
the guide louver rotate to a certain position:
1. In “Heat” mode, the unit turned on, the compressor doesn’t arrive the starting condition.
2. In “Heat” mode, the temperature arrive at the setting value and the compressor stop
running about 1min.
The operating temperature range (outdoor temperature) for cooling unit is 21℃
~
43℃;
for cooling and heating unit is -5℃
~
43℃.