5545023-YTG-G-1121
10 Johnson Controls Ducted Systems
— = Not applicable.
YFK48B21S MVC16CN21 21.0 CF/CM/CU60C 1 950 39.00 27.20 16.0 23.46
YFK48B21S MVC16CN21 21.0 CF/CM/CU60C 2 1500 47.50 36.40 16.0 13.00
YFK48B21S MVC20DN21 24.5 CF/CM/CU48D 1 950 39.00 27.00 16.5 23.83
YFK48B21S MVC20DN21 24.5 CF/CM/CU48D 2 1375 47.50 34.80 16.5 13.00
YFK48B21S MVC20DN21 24.5 CF/CM/CU60D 1 1150 40.50 30.00 17.0 24.39
YFK48B21S MVC20DN21 24.5 CF/CM/CU60D 2 1775 47.50 38.00 17.0 13.25
YFK48B21S MVC20DN21 24.5 CF/CM64D 1 1150 40.50 30.00 17.0 24.34
YFK48B21S MVC20DN21 24.5 CF/CM64D 2 1775 47.50 38.50 17.0 13.25
YFK60B21S AE60CX21 21.0 1 1450 46.69 35.58 15.0 20.75
YFK60B21S AE60CX21 21.0 2 1650 57.50 42.50 15.0 12.25
YFK60B21S AE60DX21 24.5 1 1400 47.68 35.58 16.0 21.83
YFK60B21S AE60DX21 24.5 2 1750 59.00 44.00 16.0 12.50
YFK60B21S AVC60CX21 21.0 1 1025 44.24 30.08 15.0 20.94
YFK60B21S AVC60CX21 21.0 2 1625 57.00 41.50 15.0 11.75
YFK60B21S AVC60DX21 24.5 1 1050 45.22 30.87 16.0 21.83
YFK60B21S AVC60DX21 24.5 2 1600 58.00 42.00 16.0 12.75
YFK60B21S ME14DN21 24.5 CF/CM/CU60D 1 1400 46.69 34.80 15.0 21.03
YFK60B21S ME14DN21 24.5 CF/CM/CU60D 2 1500 57.00 40.50 15.0 12.50
YFK60B21S ME14DN21 24.5 CF/CM64D 1 1375 47.18 35.19 15.5 21.32
YFK60B21S ME14DN21 24.5 CF/CM64D 2 1475 58.00 41.00 15.5 12.50
YFK60B21S ME16CN21 21.0 CF/CM/CU60C 1 1350 46.20 34.21 15.0 20.80
YFK60B21S ME16CN21 21.0 CF/CM/CU60C 2 1500 57.00 40.50 15.0 12.50
YFK60B21S ME20DN21 24.5 CF/CM/CU60D 1 1325 46.69 34.21 16.0 22.07
YFK60B21S ME20DN21 24.5 CF/CM/CU60D 2 1700 58.00 43.00 16.0 12.75
YFK60B21S ME20DN21 24.5 CF/CM64D 1 1325 47.18 34.60 16.0 22.40
YFK60B21S ME20DN21 24.5 CF/CM64D 2 1675 59.00 43.50 16.0 13.00
YFK60B21S MVC14DN21 24.5 CF/CM/CU60D 1 1000 44.24 29.88 16.0 21.69
YFK60B21S MVC14DN21 24.5 CF/CM/CU60D 2 1450 57.00 40.00 16.0 12.75
YFK60B21S MVC14DN21 24.5 CF/CM64D 1 1000 44.73 30.08 16.0 22.02
YFK60B21S MVC14DN21 24.5 CF/CM64D 2 1450 58.00 40.50 16.0 13.00
YFK60B21S MVC16CN21 21.0 CF/CM/CU60C 1 1075 44.73 31.06 15.5 21.69
YFK60B21S MVC16CN21 21.0 CF/CM/CU60C 2 1725 58.00 43.50 15.5 12.25
YFK60B21S MVC20DN21 24.5 CF/CM/CU60D 1 1150 45.71 32.05 16.0 22.30
YFK60B21S MVC20DN21 24.5 CF/CM/CU60D 2 1775 58.50 44.00 16.0 12.75
YFK60B21S MVC20DN21 24.5 CF/CM64D 1 1150 46.20 32.44 16.0 22.54
YFK60B21S MVC20DN21 24.5 CF/CM64D 2 1775 59.50 44.50 16.0 12.75
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those
conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total
electric power input in watt-hours during the same period.
1. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
SYSTEM CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
STAGE
RATED
CFM
COOLING
MODEL WIDTH
NET MBH
SEER EER
TOTAL SENS.

Related product manuals