Do you have a question about the York ZF210 and is the answer not in the manual?
Model Number | ZF210 |
---|---|
Category | Air Conditioner |
Refrigerant | R410A |
Cooling Capacity | 21000 BTU |
Heating Capacity | 22000 BTU |
Power Supply | 220-240V, 50Hz |
Sound Pressure Level (Indoor) | 45 dB(A) |
Explains the meaning of DANGER, WARNING, and CAUTION symbols.
Lists CSA certifications for unit design and application.
Provides critical safety instructions for unit installation procedures.
Details installation requirements and codes for the unit.
Specifies required clearances for unit operation and servicing.
Describes installation and adjustment of the fixed outdoor air intake damper.
Details how power wiring is brought into the unit and sized.
Provides guidelines for proper gas piping sizing and installation.
Lists key recommendations for safe and proper gas piping installation.
Discusses conversion to LP gas and requirements for its safe use.
Explains various functions driving the economizer operation.
Details the four types of free cooling options available.
Describes the power exhaust option and its settings.
How thermostats control dampers and compressors during free cooling.
Lists adjustable setpoints related to power exhaust and economizer functions.
Details the function and comments for each cover label on the economizer board.
Explains SA BUS pin connections and their functions on the economizer board.
Details analog output pins for VFD control and economizer actuators.
Details binary output pins for exhaust fan and economizer actuators.
Explains 24VAC input connections for sensors and power on the economizer board.
Details analog input terminals for humidity, supply air, and quality sensors.
Details binary input connections for purge and VFD fault contacts.
How to set the power exhaust damper position.
Explains how the AQ sensor affects damper modulation and control.
Describes the VAV option using a VFD for static pressure control.
Explains the operation of the manual bypass switch for the VFD.
Describes BAS-ready VFD models and their control wiring connections.
Demonstrates calculating corrected CFM, static pressure, and BHP at altitude.
Demonstrates determining blower speed and BHP for a given CFM and static pressure at altitude.
A step-by-step example of selecting a drive based on CFM and static pressure.
Explains how to adjust blower speed and belt tension for required CFM.
Details how compressors are controlled by thermostat inputs and safety features.
Describes how cooling system errors are monitored and handled.
How the high-pressure limit switch affects compressor operation and lockout.
Illustrates the gas valve piping configuration for ignition and main burners.
How zero volts from the high temp limit affects blower and draft motor.
How the UCB monitors the gas valve and blower operation.
Lists safety controls monitored by the ICB for gas heat units.
Explains the function of the automatic reset limit switch in the gas heat compartment.
How the centrifugal switch on the draft motor prevents ignition.
Describes the function of redundant gas valves for safety.
Explains flame sensor function and ignition control lockout.
The function of the rollout switch in preventing burner rollout.
The purpose and function of the manual reset auxiliary limit switch.
Pre-startup checks for electrical supply, thermostat, and blower rotation.
Steps for turning on the unit and setting the thermostat for cooling.
Checks to perform after the cooling system is operating.
Checks before starting the gas heat unit, including gas type and hood installation.
How to light the main burners and set the thermostat for gas heat.
Checks to perform after the heating section is operating, including gas leaks.
Chart for charging the 15-ton unit based on suction and discharge pressures.
Chart for charging the 17.5-ton unit based on suction and discharge pressures.
Chart for charging the 20-ton unit based on suction and discharge pressures.
Chart for charging the 25-ton unit based on suction and discharge pressures.
How to navigate the LCD display and the basic functions.
Step-by-step guide to navigating the LCD display menus.
Demonstrates navigating the commissioning menu to change settings.
Details the connections and functions of the Unit Control Board (UCB) terminals.
Explains thermostat connection strip terminals and their functions.
Describes the status indicators (LEDs) on the left edge of the UCB.
Details space temperature sensor connections and their functions.
Details pin temperature sensor connections for supply air.
Explains inputs for Return Air Temperature, Outside Air Temperature, and coil sensors.
Details pinned connections on the right edge of the UCB for humidity and pressure sensors.
Describes terminals at the lower right corner for output relays and heat section connections.
Details cooling and fan output connections on the UCB.
Details connections for refrigerant safety switches and blower overload.
Explains SA BUS connections for devices and gateways.
Describes the integrated user interface components like Display, Enter, Cancel, Joy.
Describes the USB connector for backup and software updates.
Details connections for the optional communication sub-board (FC BUS, EOL).
A checklist for performing unit startup and service data recording.
Details the warranty coverage for new equipment startup failures.
Instructions on using the LCD or MAP Gateway for equipment startup.
Checklist for general unit inspections before operation.
Checklist for inspecting air moving components like alignment and belt tension.
Checks related to exhaust fan operation and mounting.
Checks for economizer settings, CO2 sensor, and operation.
Table for recording nameplate and measured electrical data for unit components.
Check for proper compressor rotation using gauge pressure.
Verifying the function of the high-pressure safety system.
Verifying the function of the low-pressure safety system.
Action item to check for gas leaks in the unit piping.
Verifying the operation of the ventor motor.
Verifying the operation of primary safety controls.
Verifying the operation of auxiliary safety controls.
Verifying the operation of the rollout switch.
Verifying the operation of the smoke detector.
Action item to check manifold pressure in stages.
Action item to check supply gas pressure at full fire.
Action item to check temperature rise during gas heating operation.
Verifying proper operation of heating and cooling staging controls.
Verifying proper operation of the variable frequency drive.
Verifying all control set points are set correctly for occupancy requirements.
Ensuring all installed options are enabled and others disabled in software.
Ensuring all access panels are closed and secured after inspection.