5565606-TIM-B-1018
4 Johnson Controls Ducted Systems
Nomenclature
Z W T10 N 18 A 2 A A C 2 1 B A 8
Product Category
Z = A/C, Single Pkg., R-410A
Product Generation
7 = Seventh Generation
8 = Eighth Generation
12 = 120 MBH Input(T06,T07,T08)
18 = 180 MBH Input(T06,T07,T08,T10,T12)
24 = 240 MBH Input(T10,T12)
09 = 9 KW (T06, T07, T08)
18 = 18 KW (T06, T07, T08, T10, T12)
24 = 24 KW (T06, T07, T08, T10, T12)
36 = 36 KW (T06, T07, T08, T10, T12)
54 = 54 KW (T10, T12)
Natural Gas Heat Options
Electric Heat Options
T06 = 6.5 Ton
Nominal Cooling Capacity
T07 = 7.5 Ton
T08 = 8.5 Ton
T10 = 10.0 Ton
T12 = 12.5 Ton
Product Identifier
Voltage
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
VFD Options
A = None
B = VFD,VAV
C = VFD, w/Bypass, VAV
D = Cust Sup VFD,VAV
E = VFD, IntelliSpeed
F = VFD ,w/Bypass, Intellispeed
G = Cust Sup VFD, Intellispeed
A = No Options Installed
Installation Options
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Option
s 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Options
Filter Options
1 = 2" Throwaway Filters
2 = 2" Pleated Filters (Merv 8)
3 = 2" Cleanable Filters
4 = 4" Pleated Filters (Merv 13)
A = None
C = BACnet MSTP,Modbus,N2 COM Card
F = Fault Detection and Diagnostics (FDD)
E = Verasys Single Zone
G = Verasys Change Over Bypass
H = Hnywll Excel 10 Ctrl, DFS, APS
J = Verasys VAV
K = Verasys Single Zone W/FDD
L = Verasys COBP W/FDD
M = Verasys VAV W/FDD
N = Novar UCM Ctrl, DFS, APS
P = CPC Control, DFS, APS
Control Options
3-12.5 Ton Model Number Nomenclature
W = 12.2 EER
Airow
A = Std. Motor
D = Std. Motor/Motorized Damper (Downow Only)
H = Std Motor/Low Leak Econ/Barometric Relief (Downow
& Horizontal End Return Only)
J = Std Motor/Low Leak Econ/Power Exhaust (Downow
& Horizontal End Return Only)
N = Hi Static
R = Hi Static/Motorized Damper (Downow Only)
V = Hi Static Mtr/Low Leak Econ/Barometric Relief
(Downow & Horizontal End Return Only)
W = Hi Static Mtr/Low Leak Econ/Power Exhaust
(Downow & Horizontal End Return Only)
Heat Type
C = Cooling Only. No heat installed
A = Alum Steel, Single Stage
B = Stainless Steel Single Stage
N = Alum Steel, Two Stage
S = Stainless Steel Two Stage
Nominal Heat Capacity (Unit Size Allowed)
Cooling
00 = Cooling Only
Configuration Options
1 = Bottom Drain Composite-STD
2 = Hot Gas Bypass
3 = SS Drain Pan No/HGB
4 = SS Drain Pan W/HGB
5 = Reverse Drain Pan No/HGB
6 = Reverse Drain Pan W/HGB
A = No Options
B = Phase Monitor (PM)
C = Coil Guard (CG)
D = Dirty Filter Switch (DFS)
E = PM & CG
F = PM & DFS
G = CG & DFS
H = PM, CG, & DFS
Additional Options
Coated Coils
A = Un-Coated
B = E-Coat Cond & Evap Coils
C = E-Coat Condenser Coil
D = E-Coat Evaporator Coil