Do you have a question about the Youha TheOne and is the answer not in the manual?
Essential steps before assembling breast pump parts for expressing.
Guidelines for safe usage, sharing, and maintenance of the breast pump.
Listing and illustration of all pump parts and accessories provided.
Explanation of the battery level indicators and charging advice.
Identifies parts that do not require cleaning after each use, only prior.
Method for cleaning the motor unit and charger with a damp cloth.
Detailed steps for initial cleaning and sanitization of breast pump parts.
Procedures for cleaning breast pump parts after every use.
Method for sanitizing breast pump parts, primarily through boiling.
Instructions on how to assemble the valve base, valve, and membrane.
Guide on connecting the tubing to the motor unit and membrane cap.
How to use the breast shield converter for different breast shield sizes.
Steps for setting up the pump for double breast pumping using Y-shape tubing.
Steps for setting up the pump for single breast pumping.
Instructions on charging the breast pump motor unit.
Steps for initial pump setup, including hand washing, positioning, and locking mechanism.
How to turn on the pump and select initial massage or express modes.
How to adjust massage and express modes and control suction/cycle levels.
Steps to finish pumping, turn off the pump, and disconnect.
Instructions for preparing milk for storage or immediate feeding.
Reminder to clean and sanitize parts that came in contact with breastmilk.
Explanation of mixed mode, combining massage and express cycles.
How to customize vacuum strength and cycle length using manual mode.
Solution for condensation in tubing, involving drying the tubing.
How to address milk in tubing by checking membranes and tubing.
Troubleshooting steps for low or no suction, focusing on fit and assembly.
Advice for nipple pain, recommending consultation with a lactation specialist.
The Youha TheONE Double Electric Breast Pump is a high-quality, closed system designed to offer a comfortable and efficient way for mothers to express breastmilk. It can be used for single or double pumping, providing flexibility for different needs. The pump is designed for discreet use, making it suitable for use at home or in the office.
The Youha TheONE Double Electric Breast Pump is engineered to facilitate breastmilk expression through a combination of massage, express, and deep express modes, as well as a customizable manual mode. The pump's motor unit generates vacuum suction, which is transferred through tubing to the breast shields, stimulating milk let-down and expression. The system is designed to be a personal care item, ensuring hygiene and safety for the user.
The pump features a sleek and compact design with an easy-to-use touchscreen interface. The display shows the current mode (Express, Massage, Deep Express), vacuum indicator, vacuum setting, cycle setting, timer, and battery indicator.
Modes of Operation:
Pumping Configuration:
Battery and Charging: The pump includes a battery indicator that shows the charge level (completely charged, half full, low, or flat). When the battery is low (flashing red indicator), it requires charging. The power cable is inserted into the connection point on the left side of the motor unit, and the unit is plugged into a power outlet. The battery indicator will show a green light when fully charged. It is advised not to leave the motor unit on charge for longer than 24 hours to prevent permanent damage.
Lock Function: The On/Off button can be held for five seconds to lock the screen, preventing accidental changes during operation. A 'lock' icon will appear, and a beep will sound. To unlock, hold the On/Off button for five seconds again until a countdown from five to zero displays, followed by a double peep. This function can be used whether the pump is on or off.
Automatic Shut-off: The pump automatically shuts off after 30 minutes, aligning with common recommendations for expressing duration per session.
Breast Shield Converters: The system includes breast shield converters (size 24 to 21) to ensure a proper fit. It is crucial to ensure the converter seals completely by pressing it down along the rim of the breast shield and removing any trapped air. A dust cap is provided to keep the silicone free from dust when preparing the pump.
Proper cleaning and sanitization are essential for the safe and effective use of the Youha TheONE Double Electric Breast Pump.
Parts that Contact Breastmilk: These parts must be cleaned and sanitized before first use and after each subsequent use.
Parts that Do Not Contact Breastmilk: These parts include the motor unit, charger, tubing, tubing connector, and membrane cap. They do not require cleaning after each use but should be cleaned prior to first use and whenever necessary.
Replacement Schedule:
Care Guidelines:
The manual provides solutions for common issues such as condensation in tubing (ensure tubing is completely dry), milk in tubing (check membrane for damage, clean/sanitise/replace membrane or tubing), low or no suction (ensure correct breast shield fit, check tubing connection for single pumping, ensure all parts are assembled securely, check valves for damage/wear), and nipple pain (seek advice from a lactation consultant).
| Type | Electric |
|---|---|
| Material | BPA-Free Plastic |
| Modes | Expression, Massage |
| Flange Sizes | 24mm, 28mm |
| Power Source | Rechargeable battery |
| Display | LCD screen |
| Bottle Capacity | 150ml |