EasyManua.ls Logo

Yudo HOT RUNNER - Page 14

Yudo HOT RUNNER
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UH-02-Aug16-ENG P 14 / 21
Disassembly
1. Ensure that the system is at a temperature below 50 ° C.
2. Remove the clamping plate of the mold (plate 1), and the insulation plate when applicable.
3. Find the eyebolts placement points in the manifold (points of eyebolts that offer more resistance). Put in two
of these points which are spaced apart (when applicable).
4. Lift the system until it back off 50 mm.
5. If the system is balanced continue until it is completely out of the mold.
6. If the system is unbalanced, change the position of eyebolts to balance. After the system has already back
off of the housing 50 mm, already can use points of eyebolts off the manifold.
7. Place the system slowly on suitable surface. Take into account that the system has many hot spots that can
be easily damaged. It is recommended that this is placed upon easels seating only the manifold.
Any anomaly detected in the system must be reported to YUDO.