User Manual for YZXStudio ZY1270
Please read the user manual carefully before using.
CAUTION: Don’t calibrate the Voltage and/or Current benchmark unless you have the professional high-accuracy
equipment.
Technical Specification:
Model: ZY1270
Firmware Version: 3.0
Input Voltage Range: DC 4-24V
Input Current: Continuous -3A to 3A
Voltage Resolution: 0.0001V
Current Resolution: 0.0001A
Ah/Wh Range: 0-99999Ah0-99999Wh
Ah/Wh Resolution: 0.0001Ah0.0001Wh
Accuracy: Voltage 0.2%+2dCurrent 0.1%+2d
Display Screen: 1.3 inch 128*104 FSTN LCD Display
Screen Refresh Frequency: 3 times/second
Quiescent Current: 6mA (10mA with Backlight)
Resistor of Current Sampling: 12mΩ
Circuit Resistance: 42mΩ
Memory Type: Ferroelectric FRAM
Rewrite Cycle: 10 Billion Times
Recording Pattern: To record once Ah/Wh changed +
Load Balancing
Operation Instruction
Totally 6 operating modes, which can be shift from one to another by clicking the button.
Mode 1 To test Voltage, Current, the Ah, Wh and Temperature of the Current Ah/Wh recording group (currently
group 0 as shown in the pic middle right)
Ah/Wh Recording Group(s):
1. Totally 6 recording groups available, indicated by number from 0 to 5.
2. To shift among the recording groups, Press and Hold the button for 2
seconds and release once the group number changed.
3. To clear the Ah data of current recording group, Press and Hold the button
for 5 seconds and release once the Ah data being zeroed.
Mode 2 To test Voltage, Current, Power, Resistance and Temperature of Current Ah/Wh recording group
(currently group 0 as shown in the pic middle right)
Power of Load and Equivalent load resistance:
1. Totally 6 testing groups available, indicated by number from 0 to 5.
2. To shift among the testing groups, Press and Hold the button for 2 seconds
and release once the group number changed.
Mode 3 To test Micro Resistance value and voltage drop through charging cable
In-time Voltage Temperature
Testing Group
Current
Reference Voltage and Current Value
Resistance, and voltage drop
Current Recognition Type
Testing Method:
1. Connect the meter between the adapter/power bank and the constant current load, so as to get the Reference
Voltage and Current Value
2. Keep the constant current load on meter, unplug the meter and load combo from the adapter/power bank,
connect the target testing cable(micro USB type) between the adapter/power bank and the meter and load
Question and Answer IconNeed help?

Do you have a question about the YZXStudio ZY1270 and is the answer not in the manual?

YZXStudio ZY1270 Specifications

General IconGeneral
BrandYZXStudio
ModelZY1270
CategoryMeasuring Instruments
LanguageEnglish

Summary

Operation Instruction

Mode 1: Test Voltage, Current, Ah, Wh, Temperature

Tests Voltage, Current, Ah, Wh, and Temperature of the current Ah/Wh recording group.

Mode 2: Test Voltage, Current, Power, Resistance, Temperature

Tests Voltage, Current, Power, Resistance, and Temperature of the current Ah/Wh recording group.

Mode 3: Test Micro Resistance and Voltage Drop

Tests micro resistance value and voltage drop through charging cable.

Mode 4: Verify Charging Recognition Type

Verifies charging recognition types like Apple, DCP, QC2.0, QC3.0.

Mode 5: Dynamic Voltage and Current Curve

Draws the dynamic Voltage and Current curve.

Mode 6: Switch Off Screen Display

Switches off the screen display while Ah/Wh recording.

Settings Mode Operations

Voltage Benchmark Calibration

Calibrates voltage benchmark using a high-accuracy 10V input.

Current Benchmark Calibration

Calibrates current benchmark using a high-accuracy 2A input.

Curve Refresh Rate

Sets the curve refresh rate.

Brightness and Serial Upload Settings

Configures screen brightness and serial port upload interval.

Rotate/Invert Display

Configures display orientation (normal or inverted).

Ignore Trickle Charge

Sets minimum trickle current to filter while recording Ah.

Auto Backlight

Configures auto backlight settings.

Factory Settings

Resets device to factory default settings.

Backup and Restore Settings

Manages backup and restore operations for current settings.

Model Number and Firmware Version

Displays model number and firmware version.

Digital Font and Contrast Ratio

Configures digital font style and display contrast ratio.

Offline Curve Settings

Sets the time interval between dots for the offline curve.

Clear All Data

Clears all recorded data from the device.

Startup Delay Configuration

Sets the time for the LOGO display at startup.