14
English
Load Balance = max 32A in total
to the chargers. NB: Equal value
40A 40A 40A
Circuit breaker and dual pole RCD
type A.
Must be equal in value
on installations with several Zaptec Go.
One circuit breaker and RCD
type A per Zaptec Go.
Integrated residual
current protection
RDC-DD (6mA DC)
according to IEC 62955
Integrated open PEN fault
detection according to BS
76712018 Amendment 12020
clause 722.411.4.1 (iv)
10. Install multiple chargers