EasyManuals Logo

ZAPTEC Go User Manual

ZAPTEC Go
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
16 17
Technical specifications
Integrated RDC-DD
PARAMETER SYMBOL MIN TYP MAX
UNIT
Residual DC operating current dc 0.006 A
Operating characteristics RDC-DD according to IEC 62955
Making and breaking capacity Im 500 A
Residual making and breaking
capacity
IΔm
500 A
Rated conditional short- circuit
current
Inc
3 kA
Rated conditional residual
short-circuit current
IΔc
3 kA
Upstream circuit breaker and RCD
PARAMETER SYMBOL MIN TYP MAX
UNIT
Residual operating current
IΔn
0.03 A
Rated current In 40 A
Operating characteristics Curve C with RCD Type A according
to IEC/EN 61008-1 / 61009-1
Integrated open PEN fault detection
PARAMETER SYMBOL MIN TYP MAX
UNIT
Operating characteristics
According to BS 76712018
Amendment 12020 clause 722.411.4.1 (iv)
Operating voltage
Phase-neutral
207
253 V
English

Other manuals for ZAPTEC Go

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZAPTEC Go and is the answer not in the manual?

ZAPTEC Go Specifications

General IconGeneral
TypeElectric Vehicle Charger
Charging Power22 kW
Weight1.3 kg
Protection RatingIP54
Charging StandardIEC 61851-1
Maximum Charging Power22 kW
Protection ClassClass I
Current Output32A
ConnectivityWi-Fi, Bluetooth
Operating Temperature-30°C to +40°C
Input Voltage230/400V AC
Cable LengthNot included

Related product manuals