Trigger
You may activate the following trigger types as you wish depends on various conditions:
Motion Detection: Click it on for using Motion Detection function as a sensor. You must configure
motion detection function before taking this as the trigger. Set minimum time interval between 2
triggers, and choose the desired detection area. The detection type individually stands for the
following meanings:
Start: The trigger would be activated when the target object starts to move.
Stop: The trigger would be activated when the target object stops to move.
Start-Stop: The trigger would be activated during the target object starts to move till it stops.
Audio Detection: Click it on for using Audio Detection function as a sensor. You must configure
audio detection function before taking this as the trigger. Set minimum time interval between 2
triggers. The detection type stands for the following meanings individually:
Start: The trigger would be activated when the sound being made.
Stop: The trigger would be activated when the sound being cut off.
Start-Stop: The trigger would be activated during the sound being made and cut off.
Tampering Detection: This setting is set for the trigger will be started for the duration of tampering lasts
you configure. The duration range is from 5 seconds to 900 seconds
Digital Input: This can be set to control the external alarm input of I/O port on the rear of the device to
start the trigger.
Periodical: This can be set the certain period(by minute) to start the trigger.
On boot: The event is triggered when the IP Camera has been started over .
IR Cut Filter: This can be set the IR Cut filter mode to start the trigger.
Capacity Warning: This is triggered when SD Card capacity is be below the value you set.
Network Link Down: The event is triggered when the network get disconnected.
IP Notification: The event is triggered when the network being restarted or the IP being changed. And
there are optional network types to select, such as DHCPStatic IP and PPPoE.
PIR: Click it on for using as a sensor. You must configure tigger alternative before taking this as the
trigger. Set minimum time interval between 2 triggers.