TECHNICAL MANUAL
HeatSink
True-Cycling Refrigerated
Compressed Air Dryers
HSG Models
200-400 SCFM
ZEKS Compressed Air Solutions
1302 Goshen Parkway
West Chester, PA 19380
Phone: 610-692-9100
800-888-2323
Fax: 610-692-9192
Web: www.zeks.com
Form: TM 200-400HSG-0118
Patent No.: 6,186,223
NOTICE
Those operating the machine or performing
maintenance should read and understand the
decals positioned on the machine and
contents of this Technical Manual.
Ensure that this Technical Manual is not
removed permanently from the machine.
TM

Questions and Answers

  • A
    Andrew LloydAug 12, 2025
    Why is there a high pressure drop across my ZEKS HeatSink HSG Dehumidifier?
    • J
      Jessica GomezAug 12, 2025
      A high pressure drop across your ZEKS Dehumidifier can occur for several reasons. Ensure that both the inlet and outlet valves are fully open. If they are, the inlet and outlet filters may be blocked and require replacement. If the system operating temperature is below 32°F, turn the dryer off.
  • R
    Robert HernandezAug 18, 2025
    How to test drain valve on ZEKS Dehumidifier to stop downstream moisture?
    • H
      Hannah ThomasAug 18, 2025
      To address moisture downstream in your ZEKS Dehumidifier, start by depressing the “Drain Test” button. If the “Drain Open Light” illuminates but the valve doesn't open, check the wiring connections to ensure they are secure and that power is reaching the solenoid coil. If the valve still doesn't open, clean it.
  • M
    Miss Rhonda MooreAug 25, 2025
    What to do if drain open light does not come on in ZEKS HeatSink HSG?
    • M
      Meredith SmithAug 25, 2025
      If the “Drain Open Light” does not come on when you depress the “Drain Test” button on your ZEKS Dehumidifier, contact your distributor for assistance.
  • I
    Isaac BoydAug 30, 2025
    How to open valves of ZEKS Dehumidifier?
    • H
      Haley PalmerAug 30, 2025
      To resolve high pressure drop issues in your ZEKS Dehumidifier, open the inlet and outlet valves completely.
  • U
    uedwardsNov 4, 2025
    What to do if there is moisture downstream from my ZEKS Dehumidifier?
    • P
      pdeckerNov 5, 2025
      If you notice moisture downstream from your ZEKS Dehumidifier, several factors could be the cause. First, depress the “Drain Test” button. If the drain valve operates, then the timer may need adjustment. Also check for excessive flow, and if present, correct the cause and close the by-pass valve. Make sure the dryer has power by checking the power supply and fuses/circuit breakers. If the compressor isn't running but the fan is, clean the ambient air filter. Ensure the ambient temperature is below 120°F. If the compressor and fan aren't running and the Refrig ON light is off, reconnect the power source and restart. If the Refrig ON light is on, the compressor relay may be faulty and need replacement. Check the contactor board for loose wire connections or power loss at the control. If none...

Summary

Introduction

Abbreviated Warranty

Refrigerant Compressor Warranty

Prorated warranty for refrigerant compressors, up to 60 months.

Heat Exchanger Warranty

Refrigerated Dryer Nomenclature

Receiving and Inspection

Inspection

Inspect unit closely upon receipt for damages and note on delivery receipt.

Unpacking and Handling

Proper lifting equipment and handling procedures for dryer packages.

Safety and Operation Precautions

General Safety Rules

Essential safety rules for operating and maintaining the air dryer.

Principles of Operation

Introduction to Operation

Overview of dryer operation and key systems.

Air System Description

Description of the air system components and airflow path.

Moisture Removal System

How liquid droplets are removed from the air stream.

Refrigeration System

Components and operation of the refrigeration circuit.

Thermal Mass Circulating System

Circulation of thermal mass fluid for cooling.

Controls

Microprocessor controls and system monitoring.

Refrigerant Discharge Gauge

Monitors refrigerant gas pressure exiting the compressor.

Outlet Air Pressure Gauge

Monitors exiting compressed air pressure.

Inlet Air Temperature Gauge

Monitors compressed air temperature entering the dryer.

Compustat Controller Buttons

Description of the buttons and their functions on the Compustat controller.

Compustat Controller Lights

Explanation of indicator lights on the Compustat controller.

Compustat Controller Display

Information displayed by the Compustat controller.

Optional Weatherproof Package

Installation and Initial Start-Up

Location and Mounting

Guidelines for selecting the dryer's installation location and clearance.

Piping and Valves

Instructions for installing piping, fittings, and valves.

Filtration Requirements

Importance of prefilters and afterfilters for dryer performance.

Electrical Connection Procedures

Procedures for making electrical connections to the dryer.

Initial Dryer Start-Up

Step-by-step guide for starting up the dryer after installation.

Scheduled Maintenance

Maintenance Introduction

Overview of dryer maintenance requirements.

Refrigeration Condenser Maintenance

Maintenance of the refrigeration condenser and its filter.

Condensate Discharge System Maintenance

Procedures for checking and cleaning the automatic drain.

Troubleshooting

Troubleshooting Introduction

Guide to identifying and correcting dryer malfunctions.

Problem;Action Guide

Table listing common problems, symptoms, causes, and corrective actions.

Wiring Diagrams

General Arrangement

Parts Identification

Engineering Specifications

ZEKS HeatSink HSG Series Specifications

General IconGeneral
SeriesHSG
TypeHeatSink
BrandZEKS
Product LineHeatSink
CategoryDehumidifier