ZEN BRIGHTON - Heater, Odor & Light Bulb Fixes; Power, Display Error Solutions

ZEN BRIGHTON
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROBLEM
POSSIBLE REASON
COUNTER MEASURE
3
Infrared Heater not
heating up
* The heater is
broken
* The wire junction or
the heater’s wire is
loose
* The circuit board of
the relay is not
working
* Replace with a new heater
of the same specifications
* Check the connection /
junction and if it loose or
broken, replace it
* Replace the circuit board
4
Odour coming from sauna
* The circuits
problems
* The temperature has gone
over the high cut off range
and the power supply may
need to be replaced
* Parts of the circuitry have
broken
5
Light bulb is not working
* Light bulb has
burnt out
* Light bulb wiring is
loose
* Problems with the
electrical control
panel
* Replace the light bulb
* Replace the lamp holder
* Repair or replace it
6
Sauna does not power up
* Power cord is
unplugged
* Outlet has no
power
* Power supply or
circuit panel is
broken
* Connect power correctly
* Check outlet or circuit
breaker
* Replace the power supply
or related circuitry board
7
The temperature display
show "EP"
* The connector of
temperature sensor
is loose or sensor
damaged
* Tighten the connector of
temperature
sensor or change to a new
temperature sensor.
8
The temperature display
show "H"
* The temperature
inside the sauna
room is too high
* Turn off the unit, and
contact the manufacture.
10