EasyManua.ls Logo

Zest ZQ280 User Manual

Zest ZQ280
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
ZQ280/ZQ280A
Vector Variable Frequency Drive
Solar Inverter
Question and Answer IconNeed help?

Do you have a question about the Zest ZQ280 and is the answer not in the manual?

Zest ZQ280 Specifications

General IconGeneral
BrandZest
ModelZQ280
CategoryDC Drives
LanguageEnglish

Summary

Safety Information and Precautions

Electrical Safety

General safety guidelines for working with VFDs.

Machine/System Design and Safety of Personnel

Safety considerations for system design, installation, and maintenance.

Electrical Installation - Safety

Safety precautions for electrical installation and wiring of VFDs.

Nameplate

Type of Variable Frequency Drive

Details on different types of variable frequency drives offered.

Operating Panel

Appearance of Keyboard panel

Visual overview and description of the VFD's control panel keys.

Basic operation of panel

Explanation of fundamental operations and parameter navigation on the panel.

VFD running command mode setting

Configuration of start/stop control modes (panel vs. terminal).

VFD Frequency Setting Method Selection

Installment and Wiring

Terminal Function Instruction

Explanation of the function and connection of various terminals.

Function Parameter Specifications

F0 group-Basic running Parameters

Details on basic running parameters (F0 group) for VFD configuration.

F1 group:V/F Control Parameters

Parameters related to V/F control mode and settings.

F2 group:Vector Control Parameters

Parameters for vector control mode configuration.

F3 group: Auxiliary Operation Parameters

Parameters for auxiliary operations and specific functions.

F4 group: Auxiliary Operation 2 Parameters

F5 group: Digital Input and Output Parameters

F6 group: Analog Input and Output Parameters

F7 group: PLC、Multi-speed Parameters

F8 group: PID Control, MPPT And PV Pump Parameters

F9 group: Motor Parameters

FA group: Protect Parameters

FB group: Display And Special Parameters

FC group: Communication Control Function Parameter

DGroup-Monitoring parameter group and fault record

Fault Code Descriptions

Product Parameter Data

Parameter Data Communication Address

Defines communication addresses for reading and writing parameter data.

Product Non-Parametric Data

Data Status

Information on data status, including monitoring parameters and fault descriptions.

Inverter Fault Description

Details on inverter fault codes and their meanings.

Inverter Running Status

Information on the current running status of the inverter.

Control Parameter

Parameters for controlling the inverter's operation and outputs.

Modbus Communication Protocol

Communication Data Structure

FC Group Communication Parameter Description

Related product manuals