SECTION 3 - BASIC OPERATION
OPERATING MODE SELECTION FLOWCHART
1. Idle, wait for request to Connect
CR key received at serial computer port?
--> LOGON
LOGON:
2. Wait up to 10 seconds for CR key.
3. Print "ID=".
4. Wait up to 10 seconds for ID character(s) + CR.
ID=
P --> PROGRAMMING (Section 4)
M --> USER DATABASE PAGING (Section ЗА)
C --> FULL CAPCODE PAGING (Section ЗА)
<ESC>PG1 --> USER DATABASE AUTOMATED PAGING (Section 3B)
<ESC>PG8 --> FULL CAPCODE AUTOMATED PAGING (Section 3B)
3-4