1
2
Box Lock Hole
State Indicator
Thread Hole
3.Installation
Backup Battery
Control Panel
Air Switch
Panel Box Appearance
Panel Box Inside
Get the Panel off the track
Heat
2.Components
Thread holes
Screws
4.LED Indicators and Wire Illustration
Power Supply
Temper Switch
After the following installation, fix the panel to the track first, and then install other components.
Dissipation Hole
Control Panel
Control Panel
Panel Track
Panel Track
2
2
1
1
3) Install other components
2) Fix the box
1) Get through the thread hole
1) Meaning of LED indicators:
LINK indicator (green): Constant light indicates TCP/IP communication is normal.
ACT indicator (yellow): Flashing indicates data is transmitting through TCP/IP communication.
EXT RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
PC RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
POWER indicator (red): Light always indicates the control panel is power on.
RUN indicator (green): Flashing indicates that system is working normally.
CARD indicator (yellow): Flashing indicates card is punched on reader.
2) Recommended use of wires:
3) The auxiliary input may be connected to infrared body detectors, alarm switches, etc.
4 The auxiliary output may be connected to door bells, alarms, etc.)
5) State Indicators are connected to the panel box, which is power indicator, run status indicator and communication status indicator.
Interface Wire Specification Network cable Maximum length
Power (A) 18AWG*2PIN / 1.5M
Wie gand (B)
24AWG*6PIN
(6PIN, 8PIN, 10PIN for diffe rent
readers)
CAT-5 or above network cable, one
way DC impedance is less than 100Ω
/KM
100M
Electric Lock (C)
18AWG*2PIN+24AWG*2PIN,
18AWG*2PIN for lock connection,
24AWG*2PIN for door sensor
connection.
/ 50M
Button (D) 24AWG*2PIN / 100M
EXT485 (E)
20AWG*2PIN+24AWG*2PIN,
20AWG*2PIN for reader power
supply, 24AWG*2PIN for RS485
communic ation
CAT-5 or above network cable, one
way DC impedance less than 100 Ω
/KM. In wire connection, +12V and
GND of power supply need to be
parallel and use double wires.
Share power with control panel: 100M
Use independence power supply
(connect RS485 signal interface only):
1000M
inBIO26 0 Installation and Connection Guide
Version: 1.3 Date: Jan. 2014
1.Cautions
Please note the follo wing cautio ns. Mis-opera tio n may le ad to personal injury or
equipment failu re:
1)Do not energize the system before installa tio n is comple te ; never carr y out
installa tio n activ itie s when the system is energiz ed.
2)All perip heral devices must be gro unded.
3)The conduits of wire s under relay must be matched with metale d conduits , other wire s
can use PVC conduits .
4)It is stro ngly recommended that th e length of exposed part of any connectio n cable
should not be longer than 4 mm. Pro fessio nal cla mping tools may be used to avoid
unin te ntio nal contact of exposed wire s to avoid short- circ uit or communic atio n fa ilu re.
5)It is re commended th at card readers and butto ns be insta lle d at height of 1.4m-1.5m
above ground.
6)It is re commended to use the power supply fo r contro l panel, and exte rnal power
supply for each lock.
7)The applia nce shall be in stalle d and wire d in accord ance with natio nal ele ctric al
code and by qualifie d personnel only
Descriptio n of normal workin g state :
Connect the system to th e power supply. If the system works properly, th e POWER
indicator (red) is lit consta ntly and th e RUN indic ator (green) fla shes.
Valve regulated lea d-ac id battery :
Constan t voltage charge voltag e reg ulati on
Cycle use : 14.5V ~14.9V (25 )
Initial curren t: less tha n 2.88 A
Stan dby use: 13.6V ~13.8V (25 )
Capacity: 12V, 7.2A h/20 hr,
Battery Type: LC-R A127R2T1
Caution :
Do not charge in a gas ti ght containe r.
Do not short the battery term ina ls.
Do not inc ine rate
Flush with water at once if contact is made wit h
elec trolyte (Acid )
Do not attem pt to disasse mble the battery .