EasyManua.ls Logo

Zuden ZDAS-16CA-8 User Manual

Default Icon
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page1of 16
SYSTEM-ZDAS-16CA-8
PROGRAMMING GUIDE
Thanks for choosing
ZDAS-16CA-8
Multi-Function Alarm Control Panel. We suggest you
reading carefully this guide, operating this system strictly on the standard procedure.
ZDAS-16CA-8
is suitable for most circumstances and convenient for using, no matter its
appearance, function, or operation. We hope this Guide could answer most of your questions
when using the system.
Chapter 1 Summarize
1.1 Summarize
ZDAS-16CA-8
takes advanced microprocessor as its core technology. So it has the
advantages of high integration, very good stability, flexible function and convenient use.
1.2 Attentions before usage
Get approval from local police office before presetting the police phone number as
the alarm phone number
Ensure the system is in the correct installation, then connect AC power supply with
the panel
Only suitable for DC 12V 7AH sealed lead rechargeable storage battery, be cautious
to connect red positive line with positive terminal +, and black negative line with
negative terminal(-). The incorrect connection will cause damage of main panel.
Rechargeable current 1.5A
Avoid metal parts or hand contact to the electronic parts on the circuit when install
the lines.
Must use 2.7K resistor short unused wired zone
Mark wires to avoid miss-connection when using too many wired zones
Cut off all AC power supply, battery and telephone line before maintenance
Short JP1 when reset main panel
The 1.00MM copper-core wire from the keypad to alarm panel is up to 150 meters, 4
keypads can be connected in series
1.3 Features
High speed digital communication, compatible ADEMCO4+2, CID digital
communication protocolSend alarm signal to alarm center.
Different programmable settings, such as alarm sounds, zone types, recording,
monitoring, remote controlling, telephone number, phone line Check, and etc.
Compatible with wired and wireless function
1 group 6 bits primary passwords, 15 groups subsidiary setting passwords are
available to improve security;
Question and Answer IconNeed help?

Do you have a question about the Zuden ZDAS-16CA-8 and is the answer not in the manual?

Zuden ZDAS-16CA-8 Specifications

General IconGeneral
BrandZuden
ModelZDAS-16CA-8
CategorySecurity System
LanguageEnglish

Summary

Chapter 1 Summary

1.2 Pre-Usage Precautions

Lists crucial safety and operational precautions before using the alarm system.

Chapter 2 Installation and Connection

2.1 Wiring Diagrams

Illustrates the electrical connections for the main board and expand board.

2.2 Power Supply Connection

Details the AC and DC power connections for the alarm system.

2.3 Wired Detector Connection

Explains how to connect wired detectors, including signal and power lines.

2.5 Telephone Line Connection

Details how to connect the telephone line to the alarm panel for communication.

2.7 Keypad Installation and Addressing

Covers the physical installation and address configuration of the keypad.

Chapter 3 System Operation

3.1 System Operation Overview

Explains the main purpose and general operation of the alarm system.

3.2 Remote Controller Operation

Details how to use the remote controller for system functions like ARM and DIS-ARM.

3.3 Keypad Panel and Indicator Lights

Explains keypad layout, indicator lights, keys, and buzzer sounds for system status.

3.4 ARM Modes

Details various ARM modes including Leaving-Taking, Boundary, and Single Zone.

3.5 Disarm Operation

Details the process of disarming the alarm system using password or remote.

3.7 Telephone Alarm Reception

Explains how the system receives and handles alarms via telephone.

3.9 Stop Alarm Indicators

Procedures to stop alarm indicators and messages after an alarm event.

Chapter 4 System Settings

4.2 System Reset

Procedure to reset the system to its factory default settings.

4.7 Wireless Detector Learning

Procedure for learning and registering wireless detectors to the system.

4.9 Set Zone Type and Alarm Sound

Configuration of zone types (e.g., instant, delay) and siren status.

4.14 Set Telephone Number

Programming telephone numbers for alarm center and user notification.