1. Product Specification
Model: ZDAC-236C
Item
Index
Operating Voltage
12VDC+10%; Current 1.2A
Lock Relay
12VDC/2A
Environmental temperature
working:0~45; storage:-10~55
Relative humidity
working:40%~90%RH;storage:-20%~90%RH
RFID Card Capacity
1000 cards
4-digits public PIN Capacity
1
Proximity Reader Frequency
125KHz
Compatible Cards
EM or EM compatible cards
Card Reading Distance
515CM
2. The LED and Buzzer
Status type
Green LED
Red LED
Buzzer
Normal Working State
flash
Authorized Card Read /Valid PIN/Exit Button
Pressed
on
a short beep
Wrong PIN Entered
flash
a long beep
Non Authorized Card Read
flash
a long beep
Acceptable Key Pressed
flash
a short beep
Door Sensor, Anti-Break Sensor Alarmed
flash
continuous beeps
Programming Mode
on
flash
2 short beeps
Key In Right Programming Instruction
on
flash
2 short beeps
Key In Wrong Programming Instruction
on
flash
3 short beeps
3. The Factory Default of the Product
Type
6-digit Programming PIN
Door Open Mode
Lock Relay Time
Anti-Break Sensor Alarm
Door Sensor Alarm
Authorized Card Stored
4. Functions and Settings (All functions should be set in programming mode; the
parameters can be set repeatedly; the effective setting should be the last one.)
1. Enter programming mode:
Press [*]+[6 digits programming PIN],2 beeps;
Under programming state, it should be noted that:
1 The controller cannot perform normal function instructions.
2 If there is no programming instruction within 20 seconds, system will automatically quit
programming mode and enter the normal working mode.
3 Successfully set parameters, 2 beeps;
4 Fail to set parameters, 3 beeps;
5 Before some setting instruction is finishedi.e. the controller have already given off 2 beeps for
successful setting, or 3 beeps for failed setting, if the input instruction is mistaken, press [*], the
controller gives off a long beep, meaning that the setting of the instruction has been cancelled.
2. Change programming PIN:
Press [0]+[6 digits new programming PIN]+[repeat 6 digits new programming PIN], 2 beeps;
3. Set door open mode:
1 Card or Public PIN:
Press [1]+[0], 2 beeps;
2 Card plus Personal PIN;
Press [1]+[1], 2 beeps;
4. Set Lock Relay Time:
Press [2]+[TT], 2 beeps; TT represents unlocking time, second as unit; if unlocking time is 3 seconds,
TT=03;
5. Set Public PIN:
Press [3]+[4 digits public PIN], 2 beeps;
Press [3]+[0000], 2 beeps, eliminate all public PIN

Questions and Answers: