Do you have a question about the ZUDSEC ZDAC-236C and is the answer not in the manual?
Explains how to enter programming mode by pressing [*] and a 6-digit PIN, followed by 2 beeps.
Details on changing the programming PIN using a sequence of keys and the new PIN.
Instructions for setting door open modes, including card or public PIN, and card plus personal PIN.
Procedure to set the lock relay time using a command and time value (TT).
Guide to setting or eliminating public PINs with specific key presses.
Instructions for enabling or disabling the anti-break alarm function.
Steps for enrolling cards using card numbers or presenting cards, including confirmation and error handling.
Procedure to enable or disable the door sensor state check before unlocking.
How to delete individual authorized cards or restore factory defaults to delete all.
Instructions for enabling or disabling the door sensor alarm.
Steps to restore the controller to its original factory settings.
Method for enrolling a range of connective cards using start and end card numbers.
How to exit programming mode and return to normal working mode.
Instructions for operating the system using only a card or a public PIN.
Details on how to open the door when using both card and PIN authentication.
Important precautions to consider before and during the installation process.
Guidance on the proper installation and electrical connection procedures.
This document describes the ZDAC-236C access control device, outlining its specifications, operational features, and maintenance procedures.
The ZDAC-236C is an access control device that supports multiple door opening modes, including authorized card, public PIN, and a combination of card plus personal PIN. It features programmable settings for various security functions such as anti-break alarm, door sensor alarm, and lock relay time. The device can store up to 1000 RFID cards and supports a 4-digit public PIN. It allows for the enrollment and deletion of individual authorized cards, as well as the deletion of all cards by restoring factory defaults. The system operates in a programming mode for configuration and a normal working mode for daily operation. In programming mode, the controller cannot perform normal function instructions and will automatically exit if no instruction is received within 20 seconds.
The device uses LED lights (Green and Red) and a buzzer to indicate its status:
All functions are set in programming mode by entering [*]+[6 digits programming PIN]. Parameters can be set repeatedly, with the last setting being effective.
[*]+[6 digits programming PIN], 2 beeps.
[*] cancels the setting with a long beep.[0]+[6 digits new programming PIN]+[repeat 6 digits new programming PIN], 2 beeps.[1]+[0], 2 beeps.[1]+[1], 2 beeps.[2]+[TT], 2 beeps (TT is unlocking time in seconds, e.g., 03 for 3 seconds).[3]+[4 digits public PIN], 2 beeps. To eliminate all public PINs, press [3]+[0000], 2 beeps.[4]+[0], 2 beeps.[4]+[1], 2 beeps.[5]+[8 digits card number] or present a card to the controller. A beep, then 2 beeps confirm successful addition. To enroll more cards, repeat the process. Press [*] to finish.
[6]+[0], 2 beeps.[6]+[1], 2 beeps.[7]+[4 digits card number] or present the card to the controller, 2 beeps. Repeat for more cards. Press [*] to finish. To delete all authorized cards, restore factory defaults.[8]+[0], 2 beeps.[8]+[1], 2 beeps.[9]+[8 digits first card number]+[8 digits end card number], 2 beeps.[*], 2 beeps. If no programming instruction is received within 20 seconds, the system will automatically exit programming mode.[*] and re-enter the correct PIN.[*] and directly input the correct PIN to unlock.[8]+[6], 2 beeps, then 3 long beeps, 8 short beeps after 120 seconds, and the device enters normal working state.| Brand | ZUDSEC |
|---|---|
| Model | ZDAC-236C |
| Category | IP Access Controllers |
| Language | English |