1. Product Specification
Model: ZDAC-236C
Item
Index
Operating Voltage
12VDC+10%; Current 1.2A
Lock Relay
12VDC/2A
Environmental temperature
working:0~45; storage:-10~55
Relative humidity
working:40%~90%RH;storage:-20%~90%RH
RFID Card Capacity
1000 cards
4-digits public PIN Capacity
1
Proximity Reader Frequency
125KHz
Compatible Cards
EM or EM compatible cards
Card Reading Distance
515CM
2. The LED and Buzzer
Status type
Green LED
Red LED
Buzzer
Normal Working State
flash
Authorized Card Read /Valid PIN/Exit Button
Pressed
on
a short beep
Wrong PIN Entered
flash
a long beep
Non Authorized Card Read
flash
a long beep
Acceptable Key Pressed
flash
a short beep
Door Sensor, Anti-Break Sensor Alarmed
flash
continuous beeps
Programming Mode
on
flash
2 short beeps
Key In Right Programming Instruction
on
flash
2 short beeps
Key In Wrong Programming Instruction
on
flash
3 short beeps
3. The Factory Default of the Product
Type
6-digit Programming PIN
Door Open Mode
Lock Relay Time
Anti-Break Sensor Alarm
Door Sensor Alarm
Authorized Card Stored
4. Functions and Settings (All functions should be set in programming mode; the
parameters can be set repeatedly; the effective setting should be the last one.)
1. Enter programming mode:
Press [*]+[6 digits programming PIN],2 beeps;
Under programming state, it should be noted that:
1 The controller cannot perform normal function instructions.
2 If there is no programming instruction within 20 seconds, system will automatically quit
programming mode and enter the normal working mode.
3 Successfully set parameters, 2 beeps;
4 Fail to set parameters, 3 beeps;
5 Before some setting instruction is finishedi.e. the controller have already given off 2 beeps for
successful setting, or 3 beeps for failed setting, if the input instruction is mistaken, press [*], the
controller gives off a long beep, meaning that the setting of the instruction has been cancelled.
2. Change programming PIN:
Press [0]+[6 digits new programming PIN]+[repeat 6 digits new programming PIN], 2 beeps;
3. Set door open mode:
1 Card or Public PIN:
Press [1]+[0], 2 beeps;
2 Card plus Personal PIN;
Press [1]+[1], 2 beeps;
4. Set Lock Relay Time:
Press [2]+[TT], 2 beeps; TT represents unlocking time, second as unit; if unlocking time is 3 seconds,
TT=03;
5. Set Public PIN:
Press [3]+[4 digits public PIN], 2 beeps;
Press [3]+[0000], 2 beeps, eliminate all public PIN
Question and Answer IconNeed help?

Do you have a question about the ZUDSEC ZDAC-236C and is the answer not in the manual?

Summary

Product Specification

The LED and Buzzer

The Factory Default of the Product

Functions and Settings

Enter programming mode

Explains how to enter programming mode by pressing [*] and a 6-digit PIN, followed by 2 beeps.

Change programming PIN

Details on changing the programming PIN using a sequence of keys and the new PIN.

Set door open mode

Instructions for setting door open modes, including card or public PIN, and card plus personal PIN.

Set Lock Relay Time

Procedure to set the lock relay time using a command and time value (TT).

Set Public PIN

Guide to setting or eliminating public PINs with specific key presses.

Set Anti-Break Alarm

Instructions for enabling or disabling the anti-break alarm function.

Enrolling Cards

Steps for enrolling cards using card numbers or presenting cards, including confirmation and error handling.

Set check door sensor state before open the door

Procedure to enable or disable the door sensor state check before unlocking.

Deleting authorized card

How to delete individual authorized cards or restore factory defaults to delete all.

Set door sensor alarm state

Instructions for enabling or disabling the door sensor alarm.

Restore factory defaults

Steps to restore the controller to its original factory settings.

Enrolling A team connective Cards

Method for enrolling a range of connective cards using start and end card numbers.

Exit programming state

How to exit programming mode and return to normal working mode.

Users Instructions

Card or public PIN mode

Instructions for operating the system using only a card or a public PIN.

Door opening mode of card + PIN

Details on how to open the door when using both card and PIN authentication.

Installation

Cautions during installation

Important precautions to consider before and during the installation process.

Installation and line connection

Guidance on the proper installation and electrical connection procedures.

Force to restore factory defaults

Frequently asked questions faq

Overview

This document describes the ZDAC-236C access control device, outlining its specifications, operational features, and maintenance procedures.

Function Description

The ZDAC-236C is an access control device that supports multiple door opening modes, including authorized card, public PIN, and a combination of card plus personal PIN. It features programmable settings for various security functions such as anti-break alarm, door sensor alarm, and lock relay time. The device can store up to 1000 RFID cards and supports a 4-digit public PIN. It allows for the enrollment and deletion of individual authorized cards, as well as the deletion of all cards by restoring factory defaults. The system operates in a programming mode for configuration and a normal working mode for daily operation. In programming mode, the controller cannot perform normal function instructions and will automatically exit if no instruction is received within 20 seconds.

Important Technical Specifications

  • Model: ZDAC-236C
  • Operating Voltage: 12VDC±10%; Current 1.2A
  • Lock Relay: 12VDC/2A
  • Environmental Temperature:
    • Working: 0°C ~ 45°C
    • Storage: -10°C ~ 55°C
  • Relative Humidity:
    • Working: 40% ~ 90%RH
    • Storage: -20% ~ 90%RH
  • RFID Card Capacity: 1000 cards
  • 4-digits Public PIN Capacity: 1
  • Proximity Reader Frequency: 125KHz
  • Compatible Cards: EM or EM compatible cards
  • Card Reading Distance: 5-15CM
  • Factory Default Settings:
    • 6-digit Programming PIN: 990101
    • Door Open Mode: Authorized Card / Public PIN (Default Public PIN: 1234)
    • Lock Relay Time: 3 seconds
    • Anti-Break Sensor Alarm: Disabled
    • Door Sensor Alarm: Disabled
    • Authorized Card Stored: none

Usage Features

LED and Buzzer Indicators

The device uses LED lights (Green and Red) and a buzzer to indicate its status:

  • Normal Working State: Green LED flashes.
  • Authorized Card Read/Valid PIN/Exit Button: Green LED is on, a short beep.
  • Wrong PIN Entered: Red LED flashes, a long beep.
  • Non-Authorized Card Read: Red LED flashes, a long beep.
  • Acceptable Key Pressed: Green LED is on, a short beep.
  • Door Sensor, Anti-Break Sensor Alarmed: Red LED flashes, continuous beeps.
  • Programming Mode: Green LED is on, Red LED flashes, 2 short beeps.
  • Key In Right Programming Instruction: Green LED is on, Red LED flashes, 2 short beeps.
  • Key In Wrong Programming Instruction: Green LED is on, Red LED flashes, 3 short beeps.

Programming Functions

All functions are set in programming mode by entering [*]+[6 digits programming PIN]. Parameters can be set repeatedly, with the last setting being effective.

  • Enter Programming Mode: Press [*]+[6 digits programming PIN], 2 beeps.
    • The controller cannot perform normal function instructions in this mode.
    • If no programming instruction is received within 20 seconds, the system automatically exits programming mode.
    • Successful parameter settings are indicated by 2 beeps; failed settings by 3 beeps.
    • If an input instruction is mistaken before completion, pressing [*] cancels the setting with a long beep.
  • Change Programming PIN: Press [0]+[6 digits new programming PIN]+[repeat 6 digits new programming PIN], 2 beeps.
  • Set Door Open Mode:
    • Card or Public PIN: Press [1]+[0], 2 beeps.
    • Card plus Personal PIN: Press [1]+[1], 2 beeps.
  • Set Lock Relay Time: Press [2]+[TT], 2 beeps (TT is unlocking time in seconds, e.g., 03 for 3 seconds).
  • Set Public PIN: Press [3]+[4 digits public PIN], 2 beeps. To eliminate all public PINs, press [3]+[0000], 2 beeps.
  • Set Anti-Break Alarm:
    • Disable: Press [4]+[0], 2 beeps.
    • Enable: Press [4]+[1], 2 beeps.
  • Enrolling Cards: Press [5]+[8 digits card number] or present a card to the controller. A beep, then 2 beeps confirm successful addition. To enroll more cards, repeat the process. Press [*] to finish.
    • Note: If the rearward 4 digits of an 8-digit card number are the same for two cards, only one will be enrolled. If a card number already exists, the control will give 3 beeps.
  • Set Check Door Sensor State Before Open the Door:
    • Disable: Press [6]+[0], 2 beeps.
    • Enable: Press [6]+[1], 2 beeps.
  • Deleting Authorized Card: Press [7]+[4 digits card number] or present the card to the controller, 2 beeps. Repeat for more cards. Press [*] to finish. To delete all authorized cards, restore factory defaults.
  • Set Door Sensor Alarm State:
    • Disable: Press [8]+[0], 2 beeps.
    • Enable: Press [8]+[1], 2 beeps.
    • When enabled, the controller will emit a continuous long beep if the door is not closed after normal opening, or if the door is not opened through the controller.
  • Enrolling A Team Connective Cards: Press [9]+[8 digits first card number]+[8 digits end card number], 2 beeps.
  • Exit Programming State: Press [*], 2 beeps. If no programming instruction is received within 20 seconds, the system will automatically exit programming mode.

User Operations

  • Card or Public PIN Mode:
    • Read authorized card: Short beep, green light on, yellow light off, door opens.
    • Public PIN entered: Green light on, yellow light off, door opens. The 4-digit public PIN must be typed continuously with less than 2 seconds between key presses. If the interval exceeds 2 seconds, the system exits PIN input.
    • Wrong PIN: Press [*] and re-enter the correct PIN.
  • Door Opening Mode of Card + PIN:
    • Read authorized card: After a beep, enter the correct 4-digit Public PIN within 5 seconds. Green light on, door unlocked.
    • If PIN is not entered within 5 seconds, a long beep sounds, and the door remains locked.
    • If a wrong 4-digit PIN is entered, a long beep sounds, and the door remains locked. Re-read the card and re-enter the correct PIN.
    • If less than 4 digits are entered for the PIN, press [*] and directly input the correct PIN to unlock.
    • Read unauthorized card: A beep, then a long beep when pressing the first PIN, and the door remains locked.

Maintenance Features

Installation Guidelines

  • Avoid 100KHz-150KHz frequency sources within 50CM of the controller.
  • Maintain an installation distance of ≥50CM between two unifying machines, or one unifying machine and another 125KHz card reader.
  • When "Check door sensor when unlocking" is enabled, the controller checks the door sensor state. If the door sensor is separated, the controller considers the door already opened. In this state, the door will remain locked regardless of the door opening method, except when using the fire control door opening button.
  • Power Supply: Always cut off 12VDC power supply during installation and connection. Connecting with electricity is strictly prohibited.

Restore Factory Defaults

  • Method 1 (via programming): Press [8]+[6], 2 beeps, then 3 long beeps, 8 short beeps after 120 seconds, and the device enters normal working state.
  • Method 2 (physical reset):
    1. Remove the controller.
    2. Use metal tweezers to short connect the J2.
    3. The controller will emit a beep, then 2 beeps, and the restored factory default programming PIN is 990101.

Frequently Asked Questions

  • If the controller continuously sends out 8 short sounds after starting, it indicates insufficient power source current or voltage.

ZUDSEC ZDAC-236C Specifications

General IconGeneral
BrandZUDSEC
ModelZDAC-236C
CategoryIP Access Controllers
LanguageEnglish

Related product manuals