1.) Insert fuses (battery and mains)
(see also commissioning notes chapter 4.1, 4.2 and 4.3)
a) Mains fuses first
b) Battery fuses afterwards
Fuses inserted (battery and mains) 3 Done
2.) Enable outgoing circuits
(see also commissioning notes chapter 4.4)
Close outgoing fuses F1 - F20 for L (red) and N (blue) each
Outgoing circuits enabled 3 Done
3.) Login in
(see also commissioning notes chapter 4.5)
Login to the CPS system
Login performed 3 Done
4.) Create sub-distributions
(see also commissioning notes chapter 4.6)
a) Enter number of sub-distributions
b) Insert identification / type of SD (DALI or current circuit monitored)
c) If, on the part of the customer, particular switch inputs are required, which should be valid
throughout the SD, these must be entered in the section "special switches" (see also user
manual chapter 8.6)
Sub-distribution(s) created 3 Done
5.) Set up circuits
(see also commissioning notes chapter 4.7)
a) The available circuits must be created for each sub-distribution.
b) If, on the part of the customer, particular switch inputs are required, which should be valid
throughout the circuit, these must be entered in the section "Properties" under "switching logic
1" to switching logic 3" (see also user manual chapter 8.3)
Circuits set up 3 Done
6.) Configure and address lamps
6.1) Configuring lamps for circuit monitored sub-distributions
(see also commissioning notes chapter 4.8)
a) Select a circuit created before
b) Create all lamps which are installed in this circuit (function "new lamp")
c) Set lamp parameters (description, etc.)
d) Repeat steps a) and b) for further circuits
e) Calibrate circuit. For this purpose, select the action "Lamp calibration" in menu Test (see also
user manual chapter 6.6)
Issue date: 11/07 Page 1 of 2
Question and Answer IconNeed help?

Do you have a question about the Zumtobel ONLITE and is the answer not in the manual?

Zumtobel ONLITE Specifications

General IconGeneral
CategorySecurity Sensors
BrandZumtobel
Product LineONLITE
TypeEmergency Lighting
Lamp TypeLED
Voltage220-240 V
Frequency50/60Hz
Battery TypeNiCd or NiMH
Battery CapacityVaries depending on the model
Duration of Emergency Operation1-3 hours
Luminous FluxVaries depending on the model
DimensionsVaries depending on the model
WeightVaries depending on the model
CertificationsEN 60598
Protection RatingIP20 to IP65 (depending on the model)

Summary

Insert Fuses (Battery and Mains)

Enable Outgoing Circuits

Login to CPS System

Create Sub-distributions

Set Up Circuits

Configure and Address Lamps

Configuring Lamps for Circuit Monitored Sub-distributions

Steps for configuring lamps for sub-distributions monitored by circuit.

Configuring and Addressing Lamps for DALI Single Monitored Sub-distributions

Check System

Related product manuals