5.3 IMPORTANCE OF MAINTENANCE
Maintenance of a Proceptor unit is critical to ensure that separation eciency is not compromised. The buildup of floatables
and solids within the separator reduces the potential treatment volume and could, therefore, reduce the water retention time
within the separator resulting in reduced separation eciency. Furthermore, if contaminants are allowed to accumulate, the
maximum storage capacities may be exceeded, resulting in the release of previously captured oil, grease, and solids.
5.4 MAINTENANCE FREQUENCY
The frequency of maintenance depends on the application and the model of the Proceptor. Some applications have very little
oil, grease and/or solids in the waste stream and, therefore, reaching the maximum storage capacities will take a longer period
of time. For other applications, the maximum storage capacities will be reached in a shorter period of time. Maintenance
should be performed when the storage capacity reaches 50% or annually, whichever comes first.
The following table describes when maintenance should be performed on the various standard Proceptor models.
Preceptor Maintenance Schedu le
System
Type
Model Number
Total
Liquid
Capacity
(US gal)
Storage Capacity Maintenance Recommended
Oil/
Grease
(US gal)
Solids/
Sediment
(US gal)
Oil/
Grease
(inches)
Solids/
Sediment
(inches)
System 1:
Single Tank
GMC 50 OMC 50 50 12 11 1.0 1.5
GMC 100 OMC 100 100 42 23 4 3
GMC 150 OMC 150 150 66 48 6 5
GMC 200 OMC 200 200 90 72 8 7
GMC 250 OMC 250 250 119 91 10 8
GMC 300 OMC 300 300 156 103 13 9
GMC 500 OMC 500 500 279 87 8 3
GMC 750 OMC 750 750 410 200 11 6
GMC 1000 OMC 1000 1,000 577 295 16 9
GMC 1300 OMC 1300 1,300 707 446 19 13
GMC 1500 OMC 1500 1,500 819 540 22 15
System 2:
Two Tanks
in Series
GMC 1000(2) OMC 1000(2) 1,000 559 174 8 3
GMC 1500(2) OMC 1500(2) 1,500 819 401 11 6
GMC 2000(2) OMC 2000(2) 2,000 1.154 589 16 9
GMC 2600(2) OMC 2600(2) 2,600 1.415 891 19 13
GMC 3000(21 OMC 3000(21 3,000 1,638 1,080 22 15
GMC 4000(2) OMC 4000(2) 4,000 1,712 1,315 15 15
GMC 5000(2) OMC 5000(2) 5,000 2,226 1,776 20 19
GMC 6000(2) OMC 6000(2) 6,000 2,883 2,092 25 22
GMC 7000(2) OMC 7000(2) 7,000 3,396 2,611 30 26
System 3:
Three Tanks
in Series
GMC 8000(3) OMC 8000(3) 8,000 4,508 3,032 22 19
GMC 9000(3) OMC 9000(3) 9,000 5,115 3,542 25 22
GMC 10000(3) OMC 10000(3) 10,000 5,672 4,205 28 25

Other manuals for ZURN Proceptor OMC 50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZURN Proceptor OMC 50 and is the answer not in the manual?

ZURN Proceptor OMC 50 Specifications

General IconGeneral
BrandZURN
ModelProceptor OMC 50
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals