Do you have a question about the Zyllion ZMA-13RB and is the answer not in the manual?
Introduces the ZMA-13RB massager, highlighting its design, portability, and 4 deep-kneading massage nodes.
Lists all items provided in the Zyllion ZMA-13RB massager package, including the unit and accessories.
Illustrates and names the specific body parts for which the massager is intended.
Details essential safety rules to prevent electric shock, burns, fire, or injury during massager operation.
Advises consulting a doctor for specific health conditions and lists individuals who should avoid using the massager.
Outlines conditions requiring immediate cessation of use, including damage, overheating, or adverse physical reactions.
Provides step-by-step instructions for operating the massager, including turning it on/off and adjusting heat.
Offers solutions for common issues such as mechanical sounds, failure to power on, or grinding noises.
Identifies and labels the key components and controls of the Zyllion ZMA-13RB massager.
Explains how to clean, store, and maintain the massager to ensure its longevity and safe operation.
Details the standard one-year warranty and information on registering for an extended two-year warranty.
Confirms the product's FDA registration, indicating adherence to safety and quality guidelines.
Lists key technical details of the massager, including battery type, capacity, voltage, and usage hours.
The Zyllion ZMA-13RB is a rechargeable shiatsu massage pillow with heat, designed to provide portable and convenient massage therapy. This device is FDA listed and comes with a 1-year warranty, which can be extended to 2 years upon online registration.
The primary function of the ZMA-13RB is to deliver deep-kneading shiatsu massage with an optional heat function. It features four deep-kneading massage nodes that work to alleviate soreness and muscle tightness. The massage nodes automatically switch direction every 60 seconds, providing a varied massage experience. The integrated heat function enhances muscle soothing and relaxation. For safety and energy saving, the massager is equipped with an overheat protection device and a 15-minute auto shut-off feature.
The ZMA-13RB is designed for versatility and ease of use across various body areas. It can be used on the neck, upper back, lower back, calves, thighs, and abdomen. Its ergonomic and ultra-slim design makes it highly portable, allowing users to take it anywhere without needing to be constantly plugged in. The device comes with a power adapter set, including both a wall adapter and a car adapter, for charging flexibility.
To operate the massager, a quick press of the power button turns the unit on, automatically activating the heat feature and auto-rotation. The heat function can be toggled on or off by pressing the power button again. To completely shut off the unit, the power button should be pressed and held for 3-5 seconds. Red lights on the massage nodes flash while the device is charging and stop when fully charged, indicating it's ready for use.
For those who prefer a softer massage or are sensitive to heat, a pull-over sleeve is provided to soften both the massage and heat intensity. Adjustable velcro straps allow the massager to be secured to a chair, enhancing its utility in different settings.
It is recommended to ease into using the massager over several days to allow the body to adjust to the massage intensity. Each session should ideally be limited to 15 minutes. If the product becomes too warm, users should discontinue use and allow it to cool. If overheating persists, the unit's safety device will automatically shut off the motor. In such cases, unplugging the power cord and allowing the unit to cool for 15-20 minutes before restarting is advised.
Users should avoid using the massager outdoors, on bare skin (especially sensitive areas, inflamed areas, open sores, or areas with poor circulation), or for extended periods beyond the recommended 15 minutes. Sleeping while using the massager is not advised. The massager should not be placed directly on vertebrae but rather on the surrounding muscles.
It's crucial to consult a doctor before using the massager if any of the following apply: unusual pain, health concerns, medical care, phlebitis/thrombosis, serious medical conditions (heart disease, rheumatism, osteoporosis, tendonitis, diabetes, skin diseases, skeletal/spinal problems), pregnancy, or the presence of a pacemaker, artificial limb, or internal pins/screws.
The device should not be used if any parts are missing, damaged, or defective, or if the cover is torn. It should not be used or left near water or heated surfaces, nor submerged in liquid. If the unit falls into water while plugged in, it should be unplugged immediately. The unit should be unplugged when not in use, especially around pets or children. Children should only use the device under supervision. Metal fasteners should not be used with the device.
Avoid plugging the device into an already overloaded electrical outlet. If it gets too hot or a burning smell is detected, unplug it immediately. Always pull the power cord from the socket to remove the plug, and avoid plugging/unplugging with wet hands. Do not operate the device under a blanket or pillow, as this can cause excessive heating. Ensure air openings are not blocked by lint or hair. Avoid using the device where aerosol products are being used or oxygen is administered.
Proper care and maintenance ensure the longevity and safe operation of the ZMA-13RB. Before cleaning, ensure the unit is completely turned off and has cooled down. The device can be wiped with a soft, lightly moistened cloth for easy cleaning. Abrasive cleaning agents such as benzene, thinner, or gasoline should not be used.
The unit should be kept away from heat sources, liquids, pets, and children, especially when unsupervised. When storing, the massager unit should be kept in a cool, dry place, away from flammable products, explosives, or chemical solutions. The power cord should not be wrapped around the massager unit to prevent damage. It is important to ensure the unit does not come into contact with sharp edges or pointed objects that could damage, cut, or puncture it.
The device is not designed for commercial or medical purposes. It should only be used indoors and not in damp rooms. It is not washable and should not be dry cleaned. After 15 minutes of use, it is recommended to rest for 20 minutes before using it again.
If a fault is found, stop use immediately and unplug the power supply. Contact the seller or manufacturer for repairs or replacements. Do not attempt to repair the unit yourself, as there are no serviceable parts inside, and doing so could void the warranty and risk electric shock or injury. If the cover has torn, contact customer service for a replacement cover.
| Model | ZMA-13RB |
|---|---|
| Category | Massager |
| Type | Shiatsu Massager |
| Heat Function | Yes |
| Kneading Nodes | 4 |
| Power Source | AC Adapter |
| Frequency | 50/60Hz |
| Massage Direction | Bi-directional |
| Timer | 15 minutes |
| Material | PU Leather |
| Color | Black |
| Vibration | No |